Print Report | Back to Sample Detail

Sample Record for 2023-09-26-47

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994555 DEA: 032G7504 EFIS: 0322000154 QA Service Level: 1
DIST-CO-RTE-PM: 03-GLE-45-7.0/23.2
Work Description: FULL AND PARTIAL DEPTH RECYCLING, PLACE RHMA.
Location Description: GLENN COUNTY NEAR HAMILTON CITY FROM 4.4 MILES SOUTH TO 1.4 MILES NORTH OF BAYLISS BLUE GUM ROAD AND FROM 3.5 MILES SOUTH TO 2.5 MILES NORTH OF STONY CREEK BRIDGE
Contractor Name: BALDWIN CONTRACTING CO., INC. DBA KNIFE RIVER CONSTRUCTION
Contractor Address: 1764 Skyway, Chico, CA 95928
Resident Engineer: Dwayne Grandy Structure Rep.: Not Applicable

Sample Information

DIME Sample ID: 2023-09-26-47
TL Number from the TL Form: 715092
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Department Acceptance
Type of Material: Asphaltic Emulsion
Sample Taken Date: 09/26/2023
Date that the sample was received by the laboratory/organization performing the testing: 10/02/2023
The quantity of what the sample constitutes: 1 Jar
A brief description of the sample: SS-1H
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Western Emulsions Inc

Material Information

Emulsion Grade: SS-1h
Lot Number:
Sub Lot:

Test Results

Test 1 of 1

DIME Test ID: 2023-09-26-47-1
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Verified Date: 10/04/2023
Date Tested: 10/04/2023
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
How many beakers will be used to conduct the test? 2
Beaker 1 Residue 58.8 %
Beaker 2 Residue 58.8 %
Percentage of residue 59 %