Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 044H9004 Cty SF Rte 280 PM R0.1,R1.5 Vendor # |
|
REPORT OF LABORATORY TESTING |
||||
|
Resident Engineer: |
JOSE DAVID |
Date Reported: |
05/16/2016 |
|
|
Address: |
TL Number: |
180401 |
||
|
City: |
||||
|
Project Name: CONCRETE BARRIER, RETAINING WALL, SHOULDER AND SIDEWALK WIDENING |
||||
|
Prime Contractor: Graniterock Construction |
||||
|
Sample Taken Date: |
04/18/2016 |
Mix Design: |
na |
|
|
Contractor: Unknown |
Location : IN THE CITY AND COUNTY OF SANFRANCISCO AT ROUTE 280 SOUTHBOUND OFF-RAMP TO JOHN DALY BOULEVARD ANDAT SAN JOSE AVENUE OVERCROSSING |
|||
|
Structure unique identifier: Unknown |
||||
|
Structure name: Unknown |
||||
|
Location of Pour: Unknown |
||||
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
|---|---|---|---|---|
| 1 | 6.00 | 28.27 | 140724 | 4 |
DIME Test ID: 2016-04-18-4-1
Number of specimens: 1
Compressive strength of cylinder (to nearest 10 psi): 4980
Age of specimen: 28 days
Certified By: Mike Mullins
|
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing