Sample Record for 2016-04-12-3
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 210864 DEA: 041SS034 EFIS: 0400020869
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-580-R4.9/R5.6
Work Description: CONSTRUCT SOLDIER PILE WALL, AND RECONSTRUCTION OF LANES & SOULDERS
Location Description: IN ALAMEDA COUNTY, ON WESTBOUND OF ROUTE 580. AT PM 5.0
Contractor Name: GHILOTTI CONSTRUCTION COMPANY
Contractor Address: 2600 KITTY HAWK ROAD, LIVERMORE, CA 94551
Resident Engineer: Eddie Dike Structure Rep.: KB Singh Sandhu
Sample Information
DIME Sample ID: 2016-04-12-3
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 04/12/2016
Date that the sample was received by the laboratory/organization performing the testing: 04/13/2016
The quantity of what the sample constitutes: 190
A brief description of the sample: Bearing Pad
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber
Material Information
Mfg. Lot Number(s): 132343 2
Material/Compound/Elastomer ID: NA
Samples Representing: 190
Description (size): 1in x 8in x 12in
Comments: Unknown
Description (Number of Shims): 2
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: NA
Test Results
Test 1 of 2
DIME Test ID: 2016-04-12-3-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 05/12/2016
Date Tested: 04/14/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
55
|
Reading #2
|
55
|
Reading #3
|
56
|
Reading #4
|
57
|
Reading #5
|
57
|
Mean
|
56
|
Test 2 of 2
DIME Test ID: 2016-04-12-3-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 05/12/2016
Date Tested: 04/14/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
UTM
|
2KIP
|
Humidity
|
50 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.073 in
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
3169.4 lbf/in^2
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.07 in
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2857.1 lbf/in^2
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.07 in
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
3314.3 lbf/in^2
|
Sample 3 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
3169.4 lbf/in^2
|
Tests Assigned to this Sample
DIME Test ID | Test Method | Assigned Date | Test Date | Assigned By | Assigned Lab | Test Comments | Assigned To |
2016-04-12-3-3 | ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension | 04/14/2016 | Not scheduled | Fred Saylor | CT HQ - Sacramento Structural Materials Testing Laboratory | | |
4380