Sample Record for 2023-09-15-58
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994309 DEA: 033H5404 EFIS: 0318000012
QA Service Level: 1
DIST-CO-RTE-PM: 03-BUT-70-46.0/47.0
Work Description: RAISE ALIGNMENT, PLACE HMA, STRUCTURAL CONCRETE & BRIDGE RAIL.
Location Description: BUTTE COUNTY NEAR PARADISE FROM 0.8 MILE WEST OF SHADY REST AREA TO 0.2 MILE EAST OF SHADY REST AREA
Contractor Name: VIKING CONSTRUCTION COMPANY, INC.
Contractor Address: 11315 SUNRISE GOLD CIR. #A, RANCHO CORDOVA CA 95742
Resident Engineer: Daniel Rechs Structure Rep.: Adam Scardaci
Sample Information
DIME Sample ID: 2023-09-15-58
TL Number from the TL Form:
Sample Submitted By Organization: CT D03 - Chico Field Laboratory
Sample Organization Contact: (916) 799-4305
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 09/15/2023
Date that the sample was received by the laboratory/organization performing the testing: 09/18/2023
The quantity of what the sample constitutes: 9 cy
A brief description of the sample: PCC
From where was the sample collected: Job Site
Laboratory sample identification: 23-155
Structure unique identifier: 12-0207
Structure name:
The fabricator/manufacturer/facility name: Shasta RM
Material Information
The concrete mix design number: CT-675BD-SEA
The truck number from where the sample was collected: 41
The batch plant ticket number from where the sample was collected: 80929
Concrete batch plant: Shasta RM
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Stage-2 Deck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 1
DIME Test ID: 2023-09-15-58-3
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/25/2023
Date Tested: 09/22/2023
Submitted By Organization: CT D03 - Chico Field Laboratory
Organization Address: 2707 Notre Dame Boulevard,
Organization City: Chico
Organization State: CA
Organization Zipcode: 95928
Organization Email: bmckeehan@ghirardelliassoc.com
Organization Phone: (916) 799-4305
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 3
|
4.00 in
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
Compressive strength (to nearest 10 psi)
|
3410 psi
|
Maximum load on cylinder 1
|
43440 lb
|
Maximum load on cylinder 2
|
42000 lb
|
Maximum load on cylinder 3
|
43150 lb
|
Compressive strength of cylinder 1
|
3,455.8 psi
|
Type of fracture pattern of cylinder 1
|
3
|
Compressive strength of cylinder 2
|
3,341.3 psi
|
Compressive strength of cylinder 3
|
3,432.8 psi
|
Type of fracture pattern of cylinder 2
|
3
|
Type of fracture pattern of cylinder 3
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1.00
|
Correction factor for cylinder 2
|
1.00
|
Correction factor for cylinder 3
|
1.00
|
Age of specimen
|
7 days
|
Age of specimen in hours
|
no data0 hours
|