Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for storing JMF sample data
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2023-06-20-75
TL Number from the TL Form:
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Verification
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 06/20/2023
Date that the sample was received by the laboratory/organization performing the testing: 06/21/2023
The quantity of what the sample constitutes: JMF Verification
A brief description of the sample: 1 bag of Fine RAP
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hat Creek Construction and Materials - Shaw Pit Facility
DIME Test ID: 2023-06-20-75-1
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 09/19/2023
Date Tested: 06/28/2023
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Submitted from JMF - Ward Jenkins
Test Result Compliance:
Additional Comments When Verified:
|
Is an aggregate correction factor used?
|
No
|
|
Cumulative percent passing the 2 in. sieve
|
no data
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
no data
|
|
Cumulative percent passing the 1 in. sieve
|
no data
|
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
99 %
|
|
Cumulative percent passing the #4 sieve
|
76 %
|
|
Cumulative percent passing the #8 sieve
|
54 %
|
|
Cumulative percent passing the #16 sieve
|
39 %
|
|
Cumulative percent passing the #30 sieve
|
29 %
|
|
Cumulative percent passing the #50 sieve
|
22 %
|
|
Cumulative percent passing the #100 sieve
|
16 %
|
|
Cumulative percent passing the #200 sieve
|
12 %
|
DIME Test ID: 2023-06-20-75-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/19/2023
Date Tested: 06/28/2023
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pbr(uncorrected)=6.76%,
Pbr≈5.38%
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3035.9 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
4564.2 g
|
|
Mass of HMA Sample prior to ignition
|
1528.3 g
|
|
Corrected Asphalt Binder Content
|
6.76 %
|
|
Mass Loss
|
106.3 g
|
|
Mass of aggregate remaining after ignition
|
1422 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data0 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.2 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2023-06-20-75-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/19/2023
Date Tested: 06/28/2023
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmmr=2.511
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7335.7 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1521.8 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8251.5 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.511
|
|
Theoretical maximum density at 25°C (77°F)
|
2503.7 kg/m^3
|