Print Report | Back to Sample Detail

Sample Record for 2023-09-14-34

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995105 DEA: 023J8104 EFIS: 0222000086 QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS-3-0.408/7.1
Work Description: Scott Mountain Overlay
Location Description:
Contractor Name: TULLIS INC
Contractor Address: P O BOX 493416, REDDING CA 96049
Resident Engineer: Nicholas Riddle Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-09-14-34
TL Number from the TL Form: 824476
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Verification
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/14/2023
Date that the sample was received by the laboratory/organization performing the testing: 09/14/2023
The quantity of what the sample constitutes: 2 Boxes
A brief description of the sample: 1/2" HMA-A 25% RAP PG58-22 Valero
From where was the sample collected: Manufacturer
Laboratory sample identification: D79348
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tullis Inc. - Northstate Asphalt (Redding CA)

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2023-09-14-34-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/28/2023
Date Tested: 09/14/2023
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pb=5.60%
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3108.4 g
Mass of the specimen and specimen basket assembly prior to ignition 4733.2 g
Mass of HMA Sample prior to ignition 1624.8 g
Corrected Asphalt Binder Content 5.61 %
Mass Loss 105.6 g
Mass of aggregate remaining after ignition 1519.2 g
Correction Factor (Percent by mass of HMA Specimen) 0.71 %
Moisture Content no data0 %
Temperature Compensation Factor 0.18 %
Test Temperature 538 C