Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 995142 DEA: 120S3903 EFIS: 1220000060
QA Service Level: 1
DIST-CO-RTE-PM: 12---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2023-08-25-49
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/25/2023
Date that the sample was received by the laboratory/organization performing the testing: 08/29/2023
The quantity of what the sample constitutes: 20 BOXES OF RHMA
A brief description of the sample: 3/4" RHMA-G SP 0.4% EVO
From where was the sample collected: Manufacturer
Laboratory sample identification: 0439G-23
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA-Irvine
DIME Test ID: 2023-08-25-49-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/18/2023
Date Tested: 08/31/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests
|
2
|
What is the unit of measurement for theoretical density?
|
SI Units
|
Mass Determination
|
Air
|
Method Performed
|
no data
|
Mass of container filled with water
|
7330.1 grams
|
Mass of oven-dry sample in air for Sample 1
|
2562.1 grams
|
Mass of container filled with the sample and water for Sample 1
|
8840.7 grams
|
Mass of container filled with water
|
7330.1 grams
|
Mass of oven-dry sample in air for Sample 2
|
2554.0 grams
|
Mass of container filled with the sample and water for Sample 2
|
8839.9 grams
|
Temperature of Water
|
77 °F
|
Specific Gravity for Sample 1
|
2.437
|
Specific Gravity for Sample 2
|
2.446
|
Average Specific Gravity
|
2.442
|
Theoretical maximum density at 25°C (77°F)
|
2434.9 kg/m^3
|
DIME Test ID: 2023-08-25-49-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 09/18/2023
Date Tested: 09/01/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids
|
2.8 %
|
Percent Air Voids 2
|
2.5 %
|
Percent Air Voids 3
|
2.8 %
|
Percent Air Voids Average
|
2.7 %
|
DIME Test ID: 2023-08-25-49-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 09/18/2023
Date Tested: 09/01/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity
|
2.374
|
Bulk Specific Gravity 2
|
2.382
|
Bulk Specific Gravity 3
|
2.373
|
Average Bulk Specific Gravity
|
2.376
|
DIME Test ID: 2023-08-25-49-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/18/2023
Date Tested: 08/31/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Celsius
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
2159.0 g
|
Corrected Asphalt Binder Content
|
7.67 %
|
Mass Loss
|
168.4 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.01 %
|
Moisture Content
|
0.00 %
|
Temperature Compensation Factor
|
0.00 %
|
Test Temperature
|
538 C
|