Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 044G0804 Cty SOL Rte 80 PM R10.4/30.2 Vendor # |
|
REPORT OF LABORATORY TESTING |
||||
|
Resident Engineer: |
Justen Tatum |
Date Reported: |
07/02/2024 |
|
|
Address: |
TL Number: |
|
||
|
City: |
||||
|
Project Name: Highway widening, overhead signs, and electronic toll system. |
||||
|
Prime Contractor: O.C. JONES & SONS, INC. |
||||
|
Sample Taken Date: |
09/12/2023 |
Mix Design: |
CT063CR5W |
|
|
Contractor: Unknown |
Location : In Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing. |
|||
|
Structure unique identifier: |
||||
|
Structure name: RW 5 Footing |
||||
|
Location of Pour: |
||||
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.02 | 12.69 | 44391 | 3497.0 | 1 |
| 2 | 4.04 | 12.82 | 39120 | 3052.0 | 1 |
| 3 | 4.01 | 12.63 | 47183 | 3736 | 1 |
DIME Test ID: 2023-09-12-29-4
Number of specimens: 3
Compressive strength (to nearest 10 psi): 3430
Age of specimen: 7 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.02 | 12.69 | 54633 | 4304.0 | 1 |
| 2 | 4.02 | 12.69 | 63850 | 5031.0 | 1 |
| 3 | 4.00 | 12.57 | 56916 | 4529 | 1 |
DIME Test ID: 2023-09-12-29-5
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4620
Age of specimen: 14 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.02 | 12.69 | 63699 | 5019.0 | 1 |
| 2 | 4.02 | 12.69 | 71256 | 5614.0 | 1 |
| 3 | 4.03 | 12.76 | 69937 | 5483 | 1 |
DIME Test ID: 2023-09-12-29-6
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5370
Age of specimen: 28 days
Certified By: Spencer Adams
ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
| Temperature |
|---|
| 75 |
DIME Test ID: 2023-09-12-29-7
Certified By: Rose Saephan
ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
| Slump |
|---|
| 6.5 |
DIME Test ID: 2023-09-12-29-8
Certified By: Rose Saephan
Test ID: 2023-09-12-29-7: Performed by RMA
Test ID: 2023-09-12-29-8: Performed by RMA
|
*Subject to final inspection by the Resident Engineer. |
|
TL- Report of Laboratory Testing