Print Report | Back to Sample Detail

Sample Record for 2023-09-01-37

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994549 DEA: 032G5204 EFIS: 0321000235 QA Service Level: 1
DIST-CO-RTE-PM: 03-NEV,PLA,SIE-20,49,80-VAR
Work Description: PLACE POLYESTER CONCRETE OVERLAY AND REPLACE JOINT SEALS.
Location Description: NEVADA, PLACER AND SIERRA COUNTIES AT VARIOUS LOCATIONS
Contractor Name: AMERICAN CIVIL CONSTRUCTORS WEST COAST LLC
Contractor Address: 2990 Bay Vista Court, Suite D, Benicia, CA 94510
Resident Engineer: Tad Sampson Structure Rep.: Jimmer Ross

Sample Information

DIME Sample ID: 2023-09-01-37
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 09/01/2023
Date that the sample was received by the laboratory/organization performing the testing: 09/05/2023
The quantity of what the sample constitutes: 2 tankers
A brief description of the sample: 1 gallon can / 9800 RESIN
From where was the sample collected: Source
Laboratory sample identification: 000006
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia

Material Information

Mfg. Lot Number(s): 1488110
Batch number: 1488110
Mix number: 1488110

Test Results

Test 1 of 6

DIME Test ID: 2023-09-01-37-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 10/13/2023
Date Tested: 09/20/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Viscosity 190

Test 2 of 6

DIME Test ID: 2023-09-01-37-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 10/13/2023
Date Tested: 10/11/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Density Units pounds/gallons
Liquid Density (pounds per gallon) 9

Test 3 of 6

DIME Test ID: 2023-09-01-37-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 10/13/2023
Date Tested: 09/12/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested 5
Conditioning procedure 18/25/50+5/70
Speed of testing 0.45 in/min
Sample 1 Width 0.489 in
Sample 1 Ultimate strength 8571.4 psi
Sample 1 Thickness 0.259 in
Sample 1 Area 0.1267 in^2
Sample 1 Ultimate Strength Actual 1086 lbs
Sample 1 percent elongation 19.5 %
Sample 1 Time no data0 MM:SS
Sample 2 Width 0.49 in
Sample 2 Thickness 0.249 in
Sample 2 Area 0.122 in^2
Sample 2 Ultimate strength 8754.1 psi
Sample 2 Ultimate Strength Actual 1068 lbs
Sample 2 percent elongation 18.4 %
Sample 2 Time no data0 MM:SS
Sample 3 Width 0.49 in
Sample 3 Thickness 0.245 in
Sample 3 Area 0.1201 in^2
Sample 3 Ultimate strength 8759.4 psi
Sample 3 Ultimate Strength Actual 1052 lbs
Sample 3 percent elongation 15.8 %
Sample 3 Time no data0 MM:SS
Sample 4 Width 0.49 in
Sample 4 Thickness 0.242 in
Sample 4 Area 0.1186 in^2
Sample 4 Ultimate strength 8794.3 psi
Sample 4 Ultimate Strength Actual 1043 lbs
Sample 4 percent elongation 15 %
Sample 4 Time no data0 MM:SS
Sample 5 Width 0.49 in
Sample 5 Thickness 0.248 in
Sample 5 Area 0.1215 in^2
Sample 5 Ultimate strength 8757.2 psi
Sample 5 Ultimate Strength Actual 1064 lbs
Sample 5 percent elongation 15.9 %
Sample 5 Time no data0 MM:SS
Ultimate Strength Average 8727 psi
Percent Elongation Average 17 %

Test 4 of 6

DIME Test ID: 2023-09-01-37-4
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 10/13/2023
Date Tested: 09/20/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination 44.39

Test 5 of 6

DIME Test ID: 2023-09-01-37-5
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 10/13/2023
Date Tested: 09/13/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1 24hr
Maximum applied load (P) for Sample 1 1824 lb
Span length for Sample 1 9 in
Break location for Sample 1 bond
Specimen defects/notes for Sample 1 no data
Surface type for Sample 1 SSD
Modulus of rupture (R) for Sample 1 912 psi
Curing history for Sample 2 24hr
Maximum applied load (P) for Sample 2 1722 lb
Span length for Sample 2 9 in
Break location for Sample 2 bond
Specimen defects/notes for Sample 2 no data
Surface type for Sample 2 SSD
Modulus of rupture (R) for Sample 2 861 psi
Curing history for Sample 3 24hr
Maximum applied load (P) for Sample 3 1653 lb
Span length for Sample 3 9 in
Break location for Sample 3 bond
Specimen defects/notes for Sample 3 no data
Surface type for Sample 3 SSD
Modulus of rupture (R) for Sample 3 826.5 psi

Test 6 of 6

DIME Test ID: 2023-09-01-37-6
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 10/13/2023
Date Tested: 09/12/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid 153.9 mm
Room Temperature 77 f
Tare weight no data
Initial weight 100.04 grams
Weight at 5 minutes 99.975 grams
Weight at 10 minutes 99.908 grams
Weight at 15 minutes 99.84 grams
Weight at 20 minutes 99.785 grams
Weight at 25 minutes 99.715 grams
Weight at 30 minutes 99.644 grams
Final weight 99.64 grams
Total weight loss 0.4 grams
Calculated radius of gallon can lid in cm 7.695 cm
Lid Factor 53.757 m^2
Volatile emission 21.503 grams/m^2