Sample Record for 2023-08-25-47
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 993333 DEA: 04264724 EFIS: 0419000068
QA Service Level: 1
DIST-CO-RTE-PM: 04-MRN-101-R20.8/27.1
Work Description: CIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL.
Location Description: MARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE
Contractor Name: GHILOTTI CONSTRUCTION CO. INC. (RILEY GENAZZI & JOSH SERAFINO)
Contractor Address: 246 GHILOTTI AVE., SANTA ROSA, CA 95407
Resident Engineer: Fabio La Serna Structure Rep.: Jeremy Light
Sample Information
DIME Sample ID: 2023-08-25-47
TL Number from the TL Form:
Sample Submitted By Organization: Structure Cast
Sample Organization Contact: (661) 301-2624
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 08/25/2023
Date that the sample was received by the laboratory/organization performing the testing: 08/28/2023
The quantity of what the sample constitutes: 5 CY
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: StructureCast
Material Information
The concrete mix design number: 04-264724
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 9363
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Precast Plant
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 3
DIME Test ID: 2023-08-25-47-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Submitted By Organization: Structure Cast
Organization Address: 8261 McCutchen Road ,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93311
Organization Email: brent@structurecast.com
Organization Phone: (661) 717-5464
Data has not been verified.
Test 2 of 3
DIME Test ID: 2023-08-25-47-2
Test Method: ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Submitted By Organization: Structure Cast
Organization Address: 8261 McCutchen Road ,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93311
Organization Email: brent@structurecast.com
Organization Phone: (661) 717-5464
Data has not been verified.
Test 3 of 3
DIME Test ID: 2023-08-25-47-3
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Submitted By Organization: Structure Cast
Organization Address: 8261 McCutchen Road ,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93311
Organization Email: brent@structurecast.com
Organization Phone: (661) 717-5464
Data has not been verified.