Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994620 DEA: 120T6304 EFIS: 1222000073
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-39-3.2/5.8
Work Description: COLD PLANE AC PVMT AND PLACE RHMA.
Location Description: ORANGE COUNTY IN HUNTINGTON BEACH FROM ELLIS AVENUE/MAIN STREET TO STARK DRIVE
Contractor Name: R.J. NOBLE COMPANY
Contractor Address: 15505 E. Lincoln Ave, Orange, CA 92865
Resident Engineer: Steven Kim Structure Rep.: Unknown
DIME Sample ID: 2023-09-05-38
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/05/2023
Date that the sample was received by the laboratory/organization performing the testing: 09/08/2023
The quantity of what the sample constitutes: 20 BOXES OF HMA
A brief description of the sample: 3/4" HMA-A-SP 0.25% EVO
From where was the sample collected: Manufacturer
Laboratory sample identification: 0462A-23
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RJ Noble Orange
DIME Test ID: 2023-09-05-38-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/20/2023
Date Tested: 09/09/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of Samples
|
1
|
What is the unit of measurement for theoretical density?
|
SI Units
|
Mass Determination
|
Air
|
Method Performed
|
Mechanical Agitation - Method A
|
Mass of container filled with water 1
|
7,352.0 grams
|
Mass of oven-dry sample in air for Sample 1
|
2,560.4 grams
|
Mass of container filled with the sample and water for Sample 1
|
8,899.2 grams
|
Temperature of Water
|
77 °F
|
Specific Gravity for Sample 1
|
2.527
|
Theoretical maximum density at 25°C (77°F)
|
2520 kg/m^3
|
DIME Test ID: 2023-09-05-38-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 09/20/2023
Date Tested: 09/11/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids
|
4.8 %
|
Percent Air Voids 2
|
4.5 %
|
Percent Air Voids 3
|
4.6 %
|
Average Percent Air Voids
|
4.6 %
|
DIME Test ID: 2023-09-05-38-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 09/20/2023
Date Tested: 09/11/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity
|
2.405
|
Bulk Specific Gravity 2
|
2.413
|
Bulk Specific Gravity 3
|
2.412
|
Average Bulk Specific Gravity
|
2.410
|
DIME Test ID: 2023-09-05-38-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/20/2023
Date Tested: 09/09/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Celsius
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
2,122.0 g
|
Corrected Asphalt Binder Content
|
5.01 %
|
Mass Loss
|
117.2 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.37 %
|
Moisture Content
|
0.00 %
|
Temperature Compensation Factor
|
0.14 %
|
Test Temperature
|
538 C
|