Print Report | Back to Sample Detail

Sample Record for 2016-03-15-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 8196 DEA: 59912684 QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2016-03-15-6
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 03/15/2016
Date that the sample was received by the laboratory/organization performing the testing: 03/22/2016
The quantity of what the sample constitutes: 474
A brief description of the sample: .5 Prestressing Strand
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire

Material Information

Comments: Unknown
Reel/Coil/Pack Number(s): S128907-5, S128910-2, S128910-4, S128913-2, S128917-7, S128922-3, S128922-6, S128923-3, S128924-3, S128927-2, S128927-5, S128928-5, S128928-6, S128929-6, S128932-1, S128934-2, S128935-2, S128936-2, S128936-6, S128939-2, S128940-2, S128941-1, S128941-4, S128943-1, S128943-3
Number of Coils: 25
Group Number: 10842
Strand Diameter:
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0533615-2, S0533815-2, S0599315-2, S0533715-2, S0534015-3, S0524215, S0524315, S0533215, S0533215-2, S0524915-3, S0524815-3, S0524715-3, S0524615, S0524515-5, S0516916
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden Wire

Test Results

Test

DIME Test ID: 2016-03-15-6-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Verified Date: 03/29/2016
Date Tested: 03/23/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 25
Dia of the Center Wire (in)Dia of the Outer Wire 1 (in)Dia of the Outer Wire 2 (in)Dia of the Outer Wire 3 (in)Dia of the Outer Wire 4 (in)Dia of the Outer Wire 5 (in)Dia of the Outer Wire 6 (in)Area (sqin)
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152

Test

DIME Test ID: 2016-03-15-6-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 03/29/2016
Date Tested: 03/23/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 25
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
SO533615-2S128907-50.152430914025428.61.81Brian
SO533815-2S128910-20.15242863281.68Brian
SO533815-2S128910-40.1524294328.81.65Brian
SO599315-2S128913-20.1524339328.41.61Brian
SO533715-2S128917-70.1524309128.51.78Brian
SO534015-3S128922-30.15242711281.67Brian
SO534015-3S128922-60.1524299728.81.63Brian
SO524215S128923-30.1524291226.51.63Brian
SO524215S128924-30.1524269628.61.76Brian
SO524315S128927-20.1524258828.11.66Brian
SO524315S128927-50.1524287727.11.75Brian
SO533215S128928-50.1524253828.31.72Brian
SO533215S128928-60.1524220628.31.73Brian
SO533215-2S128929-60.1524223828.11.67Brian
SO524915-3S128932-10.1524269828.41.67Brian
SO5244815-3S128934-20.1524278328.41.81Brian
SO5244815-3S128935-20.1524253727.21.59Brian
SO524715-3S128936-20.1524286728.51.84Brian
SO524715-3S128936-60.1524301228.11.78Brian
SO524615S128939-20.1524284128.61.74Brian
S0524615S128940-20.1524262628.11.73Brian
S0524515-3S128941-10.1524294128.31.76Brian
S0524515-3S128941-40.15242979281.69Brian
S0516916S128943-10.1524255828.21.75Brian
S0516916S128943-30.1524277528.31.67Brian
UTM 120KIP
Temperature 70 F
Extensometers E88766