Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994785 DEA: 023H32U4 EFIS: 0221000164
QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS-I5-2.5/R15.9
Work Description: Roadway rehabilitation and bridge improvements along I5 in Mount Shasta
Location Description: SIS I5 2.5/R15.9
Contractor Name: Gordon Stout - Walsh/Myers
Contractor Address: 1390 Willow Pass Rd Suite 950, Concord, CA 94520
Resident Engineer: Austin Henry Structure Rep.: Mike Sears
DIME Sample ID: 2023-06-19-67
TL Number from the TL Form: 851257
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/19/2023
Date that the sample was received by the laboratory/organization performing the testing: 06/19/2023
The quantity of what the sample constitutes: Production Start-Up Evaluation
A brief description of the sample: 16 boxes of Lime Treated 3/4-inch Type A HMA (eq. PG 64-28 M) with 24.0% RAP and virgin PG 58-34 M from Valero Benicia
From where was the sample collected: Manufacturer
Laboratory sample identification: D79277
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tullis – Northstate Asphalt (Redding, CA)
DIME Test ID: 2023-06-19-67-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/15/2023
Date Tested: 09/06/2023
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pb=5.68%
Test Result Compliance: does not comply
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3109.3 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5171.7 g
|
|
Mass of HMA Sample prior to ignition
|
2062.4 g
|
|
Corrected Asphalt Binder Content
|
5.67 %
|
|
Mass Loss
|
129.5 g
|
|
Mass of aggregate remaining after ignition
|
1932.9 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.46 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.15 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2023-06-19-67-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/15/2023
Date Tested: 06/21/2023
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmm=2.488
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7335.7 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2511 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8837.4 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.488
|
|
Theoretical maximum density at 25°C (77°F)
|
2480.8 kg/m^3
|
DIME Test ID: 2023-06-19-67-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 09/15/2023
Date Tested: 06/27/2023
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmb=2.432
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.432
|
|
Bulk Specific Gravity 2
|
2.434
|
|
Bulk Specific Gravity 3
|
2.431
|
|
Average Bulk Specific Gravity
|
2.432
|
DIME Test ID: 2023-06-19-67-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 09/15/2023
Date Tested: 09/05/2023
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pa=2.2%,
VMA=13.2%,
VFA=83.1%,
DP=1.3
Test Result Compliance: does not comply
Additional Comments When Verified:
|
Percent Air Voids
|
2.3 %
|
|
Percent Air Voids 2
|
2.2 %
|
|
Percent Air Voids 3
|
2.3 %
|
|
Average Percent Air Voids
|
2.3 %
|
DIME Test ID: 2023-06-19-67-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 09/15/2023
Date Tested: 07/11/2023
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: S1=110psi,
S2=106psi,
TSR=97%
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
110 psi
|
|
Average Wet Tensile Strength
|
106 psi
|
|
Tensile Strength Ratio
|
0.96
|
DIME Test ID: 2023-06-19-67-6
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 09/15/2023
Date Tested: 07/31/2023
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: CT389:
Nf>15000,
SIP>15000,
CT360:
SA=0.1g/cm²
Test Result Compliance: complies
Additional Comments When Verified:
|
Specimen Preparation Method
|
no data
|
|
Test Temperature
|
122 F
|
|
Air Void Content for specimen A-1
|
no data
|
|
Air Void Content for specimen A-2
|
no data
|
|
Air Void Content for specimen B-1
|
no data
|
|
Air Void Content for specimen B-2
|
no data
|
|
Stripping Inflection Point (Wheel A)
|
>15000
|
|
Stripping Inflection Point (Wheel B)
|
>15000
|
|
Maximum impression at 5000 passes (left wheel)
|
1.43 mm
|
|
Maximum impression at 5000 passes (right wheel)
|
1.55 mm
|
|
Average impression at 5000 passes (left/right avg)
|
1.49 mm
|
|
Maximum impression at 10000 passes (left wheel)
|
1.65 mm
|
|
Maximum impression at 10000 passes (right wheel)
|
1.85 mm
|
|
Average impression at 10000 passes (left/right avg)
|
1.75 mm
|
|
Maximum impression at 15000 passes (left wheel)
|
1.88 mm
|
|
Maximum impression at 15000 passes (right wheel)
|
1.96 mm
|
|
Average impression at 15000 passes (left/right avg)
|
1.92 mm
|
|
Average impression at 20000 passes (left/right avg)
|
no data
|
|
Average impression at 25000 passes (left/right avg)
|
no data
|