Sample Record for 2023-08-23-72
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 215445 DEA: 100X7504 EFIS: 1013000009
QA Service Level: 1
DIST-CO-RTE-PM: 10-ALP-4,88,89-var
Work Description: REPLACE BRIDGE RAIL, BARRIER SLAB AND GUARDRAIL.
Location Description: ALPINE COUNTY AT VARIOUS LOCATIONS
Contractor Name: BRIDGEWAY CIVIL CONSTRUCTORS, INC.
Contractor Address: 3333 Vaca Valley Parkway, Suite 2000, Vacaville, CA 95688
Resident Engineer: Pawan Garg Structure Rep.: John Cooley
Sample Information
DIME Sample ID: 2023-08-23-72
TL Number from the TL Form: TL502 79399
Sample Submitted By Organization: CT D10 - Stockton Field Laboratory
Sample Organization Contact: (559) 230-3109
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 08/23/2023
Date that the sample was received by the laboratory/organization performing the testing: 08/24/2023
The quantity of what the sample constitutes: (3) 4x8 Test Cylinders
A brief description of the sample: Fiber Deck Mix
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: 31-0022
Structure name:
The fabricator/manufacturer/facility name: Not Provided
Material Information
The concrete mix design number: D673A
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: Not Provided
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Transit Truck Chute
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 4
DIME Test ID: 2023-08-23-72-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 09/20/2023
Date Tested: 09/13/2023
Submitted By Organization: CT D10 - Stockton Field Laboratory
Organization Address: 1976 East Dr. Martin Luther King Jr. Boulevard,
Organization City: Stockton
Organization State: CA
Organization Zipcode: 95205
Organization Email: mandeep.dhesi@dot.ca.gov
Organization Phone: (209) 948-7567
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
5260 psi
|
|
Maximum load on cylinder 1
|
68090 lb
|
|
Maximum load on cylinder 2
|
65060 lb
|
|
Maximum load on cylinder 3
|
65350 lb
|
|
Compressive strength of cylinder 1
|
5416.9 psi
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Compressive strength of cylinder 2
|
5175.8 psi
|
|
Compressive strength of cylinder 3
|
5198.9 psi
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
21 days
|
|
Age of specimen in hours
|
no data0 hours
|
Test 2 of 4
DIME Test ID: 2023-08-23-72-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 09/20/2023
Date Tested: 09/06/2023
Submitted By Organization: CT D10 - Stockton Field Laboratory
Organization Address: 1976 East Dr. Martin Luther King Jr. Boulevard,
Organization City: Stockton
Organization State: CA
Organization Zipcode: 95205
Organization Email: mandeep.dhesi@dot.ca.gov
Organization Phone: (209) 948-7567
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
4440 psi
|
|
Maximum load on cylinder 1
|
52480 lb
|
|
Maximum load on cylinder 2
|
58200 lb
|
|
Maximum load on cylinder 3
|
56730 lb
|
|
Compressive strength of cylinder 1
|
4175.0 psi
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Compressive strength of cylinder 2
|
4630.1 psi
|
|
Compressive strength of cylinder 3
|
4513.1 psi
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
14 days
|
|
Age of specimen in hours
|
no data0 hours
|
Test 3 of 4
DIME Test ID: 2023-08-23-72-3
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 09/20/2023
Date Tested: 08/30/2023
Submitted By Organization: CT D10 - Stockton Field Laboratory
Organization Address: 1976 East Dr. Martin Luther King Jr. Boulevard,
Organization City: Stockton
Organization State: CA
Organization Zipcode: 95205
Organization Email: mandeep.dhesi@dot.ca.gov
Organization Phone: (209) 948-7567
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
3520 psi
|
|
Maximum load on cylinder 1
|
46340 lb
|
|
Maximum load on cylinder 2
|
43470 lb
|
|
Maximum load on cylinder 3
|
42780 lb
|
|
Compressive strength of cylinder 1
|
3686.6 psi
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Compressive strength of cylinder 2
|
3458.2 psi
|
|
Compressive strength of cylinder 3
|
3403.3 psi
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
7 days
|
|
Age of specimen in hours
|
no data0 hours
|
Test 4 of 4
DIME Test ID: 2023-08-23-72-4
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 09/20/2023
Date Tested: 09/20/2023
Submitted By Organization: CT D10 - Stockton Field Laboratory
Organization Address: 1976 East Dr. Martin Luther King Jr. Boulevard,
Organization City: Stockton
Organization State: CA
Organization Zipcode: 95205
Organization Email: mandeep.dhesi@dot.ca.gov
Organization Phone: (209) 948-7567
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of specimens
|
3
|
|
Average Compressive Strength (to nearest 10)
|
5580 lb/in^2
|
|
Cylinder Age
|
28 days
|
|
Break Description of Cylinder 1 (if not 'cone')
|
Type B
|
|
Break Description of Cylinder 2 (if not 'cone')
|
Type B
|
|
Break Description of Cylinder 3 (if not 'cone')
|
Type C
|