Sample Record for 2023-07-11-68

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994812 DEA: 042K7204 EFIS: 0417000014 QA Service Level: 1
DIST-CO-RTE-PM: 04-CC-4-R14.3/24.3
Work Description: Pvmt rehabilitation, slab repl, ADA curb ramp and install guardrail.
Location Description: On state highway in Contra Costa County in and near Concord and Pittsburg from 0.3 miles east of Peralta Road Undercrossing to Loveridge Road Overcrossing.
Contractor Name: O.C. Jones & Sons, Inc. (Victor Babbitt)
Contractor Address: 1520 Fourth Street, Berkeley, CA 94710
Resident Engineer: Rabi Mukherjee Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-07-11-68
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Concord Field Laboratory
Sample Organization Contact: (510) 714-7019
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/11/2023
Date that the sample was received by the laboratory/organization performing the testing: 07/14/2023
The quantity of what the sample constitutes: 3 beams
A brief description of the sample: PCC Beams
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: HWY 4
The fabricator/manufacturer/facility name: Vanguard / G3

Material Information

The concrete mix design number: HE4X4BM
The truck number from where the sample was collected: 0000
The batch plant ticket number from where the sample was collected: 0000
Concrete batch plant: Vanguard
The fabricator/manufacturer designation for the sample: 0
A detailed description of where the material sample was collected: Concrete Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2023-07-11-68-6
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 08/28/2023
Date Tested: 07/14/2023
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test: Vanguard Mobile Plant Martinez
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens 3
Does the testing machine measure load or stress on the beam specimen? Load
Fracture initiates in the tension surface Within the Middle Third of the Span Length
Fracture occurred at a capped section Yes
Is a beam dimensional correction factor used? Yes
Age of specimen 3 days
Modulus of rupture 780 psi
Modulus of rupture average 730 psi
Modulus of rupture 2 720 psi
Modulus of rupture 3 680 psi

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2023-07-11-68-1CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete08/28/2023Not scheduledIGNACIO ARECHIGACT D04 - Concord Field Laboratoryno samples Break- strong than required
2023-07-11-68-2CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete08/28/2023Not scheduledIGNACIO ARECHIGACT D04 - Concord Field LaboratoryBeam did not break stopped tested after passing PSI requirement
2023-07-11-68-3CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete08/28/2023Not scheduledIGNACIO ARECHIGACT D04 - Concord Field LaboratoryBeams did not break they were brought to above passing and then stopped
2023-07-11-68-4CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete08/28/2023Not scheduledIGNACIO ARECHIGACT D04 - Concord Field LaboratoryVanguard Mobile Plant Martinez
2023-07-11-68-5CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete08/28/2023Not scheduledIGNACIO ARECHIGACT D04 - Concord Field Laboratory