Print Report | Back to Sample Detail

Sample Record for 2023-08-22-37

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994620 DEA: 120T6304 EFIS: 1222000073 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-39-3.2/5.8
Work Description: COLD PLANE AC PVMT AND PLACE RHMA.
Location Description: ORANGE COUNTY IN HUNTINGTON BEACH FROM ELLIS AVENUE/MAIN STREET TO STARK DRIVE
Contractor Name: R.J. NOBLE COMPANY
Contractor Address: 15505 E. Lincoln Ave, Orange, CA 92865
Resident Engineer: Steven Kim Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-08-22-37
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/22/2023
Date that the sample was received by the laboratory/organization performing the testing: 08/25/2023
The quantity of what the sample constitutes: 18 BOXES OF RHMA
A brief description of the sample: 1/2" RHMA-G 1.0% LSM
From where was the sample collected: Manufacturer
Laboratory sample identification: 0435G-23
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RJ Noble Orange

Material Information

HMA Type: RHMA-G
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number: 50R003ARSPWEO
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 4

DIME Test ID: 2023-08-22-37-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/18/2023
Date Tested: 08/30/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7330.2 grams
Mass of oven-dry sample in air for Sample 1 1565.2 grams
Mass of container filled with the sample and water for Sample 1 8256.8 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.451
Theoretical maximum density at 25°C (77°F) 2443.9 kg/m^3

Test 2 of 4

DIME Test ID: 2023-08-22-37-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 09/18/2023
Date Tested: 08/31/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
Percent Air Voids 6.1 %
Percent Air Voids 2 6.1 %
Percent Air Voids 3 6.1 %
Average Percent Air Voids 6.1 %

Test 3 of 4

DIME Test ID: 2023-08-22-37-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 09/18/2023
Date Tested: 08/31/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.302
Bulk Specific Gravity 2 2.302
Bulk Specific Gravity 3 2.302
Average Bulk Specific Gravity 2.302

Test 4 of 4

DIME Test ID: 2023-08-22-37-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/18/2023
Date Tested: 08/31/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 1638 g
Corrected Asphalt Binder Content 6.98 %
Mass Loss 124.7 g
Correction Factor (Percent by mass of HMA Specimen) 0.36 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C