Print Report | Back to Sample Detail

Sample Record for 2023-08-17-53

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993318 DEA: 11423704 EFIS: 1116000059 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-8-R31.8/R41.7
Work Description: PLACE CRCP, HMA, MGS, AND WATER POLLUTION CONTROL SYSTEM.
Location Description: SAN DIEGO COUNTY NEAR ALPINE FROM VIEJAS CREEK BRIDGE TO PINE VALLEY CREEK BRIDGE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5860 El Camino Real, Ste 200, Carlsbad, CA 92008
Resident Engineer: Art Pannu Structure Rep.: Carlos Guzman

Sample Information

DIME Sample ID: 2023-08-17-53
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Aggregate
Sample Taken Date: 08/17/2023
Date that the sample was received by the laboratory/organization performing the testing: 08/18/2023
The quantity of what the sample constitutes: 8 boxes 3 bags
A brief description of the sample: 1/2" HMA
From where was the sample collected: Source
Laboratory sample identification: 6525-PSU
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CCA Lakeside

Material Information

Source Identification (SMARA, name of Pit or Job Site): Hanson Vigilante Rd.
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 10

DIME Test ID: 2023-08-17-53-10
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 10/06/2023
Date Tested: 08/29/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Is an aggregate correction factor used? No
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 100 %
Cumulative percent passing the #4 sieve 72 %
Cumulative percent passing the #8 sieve 54 %
Cumulative percent passing the #16 sieve 41 %
Cumulative percent passing the #30 sieve 31 %
Cumulative percent passing the #50 sieve 21 %
Cumulative percent passing the #100 sieve 14 %
Cumulative percent passing the #200 sieve 9.3 %

Test 2 of 10

DIME Test ID: 2023-08-17-53-8
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 10/06/2023
Date Tested: 09/12/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Grading designation B
Mass of sample on No.12 sieve (after 500 revolutions) 3798 grams
Percent loss after 100 revolutions 11 %
Percent loss after 500 revolutions 24 %

Test 3 of 10

DIME Test ID: 2023-08-17-53-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 10/06/2023
Date Tested: 08/29/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 99 %
Cumulative percent passing the 3/8 in. sieve 80 %
Cumulative percent passing the #4 sieve 62 %
Cumulative percent passing the #8 sieve 45 %
Cumulative percent passing the #16 sieve 39 %
Cumulative percent passing the #30 sieve 24 %
Cumulative percent passing the #50 sieve 18 %
Cumulative percent passing the #100 sieve 11 %
Cumulative percent passing the #200 sieve 7.1 %

Test 4 of 10

DIME Test ID: 2023-08-17-53-4
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 10/06/2023
Date Tested: 08/29/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Sand Equivalent 57

Test 5 of 10

DIME Test ID: 2023-08-17-53-5
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Verified Date: 10/06/2023
Date Tested: 08/29/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Plastic limit (PL) 1 %

Test 6 of 10

DIME Test ID: 2023-08-17-53-3
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 10/06/2023
Date Tested: 09/13/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method B
Determination By Number
Dimensional ratio used 5:1
Weighted percentage of particles (by number) that were flat and elongated 0 %
Weighted percentage of particles (by number) that were not flat and elongated 0 %

Test 7 of 10

DIME Test ID: 2023-08-17-53-2
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 10/06/2023
Date Tested: 08/29/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method 1 - Combined Fracture Determination
Aggregate Size and Fracture Type Coarse 2 Faced and Fine 1 Faced
Percentage of questionable, coarse, 2 faced particles tested no data0 %
Percentage of questionable, fine, 1 faced particles tested no data0 %
Percentage of fractured, coarse, 2 faced particles tested 98 %
Percentage of fractured, fine, 1 faced particles tested 100 %

Test 8 of 10

DIME Test ID: 2023-08-17-53-7
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 10/06/2023
Date Tested: 08/29/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Basis for relative density testing Bulk
Specific Gravity 2.563
Absorption 1.6 %

Test 9 of 10

DIME Test ID: 2023-08-17-53-6
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 10/06/2023
Date Tested: 09/13/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Bulk specific gravity 2.573
Bulk specific gravity (SSD Basis) 2.620
Apparent specific gravity 2.699
Absorption 1.8 %

Test 10 of 10

DIME Test ID: 2023-08-17-53-9
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 10/06/2023
Date Tested: 08/29/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What test method is performed? Method A
Bulk dry specific gravity 2.573
Average uncompacted voids 45.3 %