Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214830 DEA: 043G6304 EFIS: 0412000409
QA Service Level: 1
DIST-CO-RTE-PM: 04-SCL-4-SCl-9 -4.75/4.9
Work Description: Saratoga Creek Bridge Rehabilitation Project
Location Description: San Jose - Saratoga Creek
Contractor Name: Myers and Sons
Contractor Address: 4600 NORTHGATE BLVD, STE 100, SACRAMENTO, CA 95834
Resident Engineer: Arif Khan Structure Rep.: OANH BUI
DIME Sample ID: 2023-08-23-21
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 08/23/2023
Date that the sample was received by the laboratory/organization performing the testing: 08/29/2023
The quantity of what the sample constitutes: 1 lot of 104
A brief description of the sample: High Strength Bolts
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier: 37-0074
Structure name: Saratoga Creek Bridge
The fabricator/manufacturer/facility name: St. Louis Screw & Bolt
Rocap Number(s): TT0169273
Heat Number(s): 10821890
Nut Mfg. Lot Number(s): N/A
Washer Mfg. Lot Number(s): N/A
Bolt Specification: ASTM A325
Bolt Length(s): 1-1/2"
Nut Specification: NA
Washer Specification: NA
Finish: ASTM A153/F2329 Hot Dip
Diameter/Size: 1/2"
Bolt Mfg. Lot Number: E671J1
Rocap Test Requirement(s):
Lubricant Requirements(s): yes
DIME Test ID: 2023-08-23-21-1
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 09/07/2023
Date Tested: 09/01/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E671J1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.5 in
|
Bolt Length
|
1.5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2023-08-23-21-2
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 09/07/2023
Date Tested: 09/01/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E671J1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.5 in
|
Bolt Length
|
1.5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2023-08-23-21-3
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/07/2023
Date Tested: 09/01/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E671J1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.5 in
|
Bolt Length
|
1.5 in
|
Measurement Average
|
3 mils
|
DIME Test ID: 2023-08-23-21-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/07/2023
Date Tested: 09/01/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E671J1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.5 in
|
Bolt Length
|
1.5 in
|
Measurement Average
|
4.3 mils
|
DIME Test ID: 2023-08-23-21-5
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 09/07/2023
Date Tested: 09/01/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E671J1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.5 in
|
Bolt Length
|
1.5 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
27.32
|
Spacing
|
Ok
|
DIME Test ID: 2023-08-23-21-6
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 09/07/2023
Date Tested: 09/01/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E671J1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.5 in
|
Bolt Length
|
1.5 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
25.5
|
Spacing
|
Ok
|