Print Report | Back to Sample Detail

Sample Record for 2023-08-15-31

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994780 DEA: 070W3304 EFIS: 0721000265 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-10-19.5/29.5
Work Description: LOS ANGELES COUNTY FROM EVERGREEN AVENUE PEDESTRIAN OVERCROSSING IN LOS ANGELES TO VALLEY BOULEVARD UNDERCROSSING IN EL MONTE
Location Description: DIGOUTS, SLURRY SEAL, COLD PLANE OVERLAY,
Contractor Name: GRIFFITH COMPANY
Contractor Address: Unknown
Resident Engineer: Sushilkumar Chaudhari Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-08-15-31
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/15/2023
Date that the sample was received by the laboratory/organization performing the testing: 08/17/2023
The quantity of what the sample constitutes: 4 BOXES OF RHMA
A brief description of the sample: 3/4" RHMA-G-SP 0.5% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0417G-23
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Irwindale

Material Information

HMA Type: RHMA-G
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 226108M IRW LTR
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2023-08-15-31-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/23/2023
Date Tested: 08/19/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2123 g
Corrected Asphalt Binder Content 7.69 %
Mass Loss 175 g
Correction Factor (Percent by mass of HMA Specimen) -0.41 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C