Project ID: 212737 DEA: 060S8304 EFIS: 0615000046
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-5-44.4-45.4
Work Description: TUMEY GULCH ABUTMENT REHAB BR# 42-0246L/R.
Location Description: IN FRESNO COUNTY AT TUMEY GULCH.
Contractor Name: Bruce Shumacher
Contractor Address: 2716 S Granite Ct, Fresno, CA 93706
Resident Engineer: Cary Cruz Structure Rep.: Ben Holton
DIME Sample ID: 2023-08-01-68
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 417-5341
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 08/01/2023
Date that the sample was received by the laboratory/organization performing the testing: 08/02/2023
The quantity of what the sample constitutes: Cyliners
A brief description of the sample: PCC cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Don Chapin - Los Banos Plant
The concrete mix design number: G67S34S
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 420823
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2023-08-01-68-2
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/14/2023
Date Tested: 08/08/2023
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 3240 North Millbrook Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93726
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test: 7 day
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
no data
|
Apparent mass of submerged cylinder 1
|
no data0 lb
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.01 in
|
Average diameter of cylinder 3
|
4.00 in
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
Cross sectional area of cylinder 2
|
12.63 in^2
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
Compressive strength (to nearest 10 psi)
|
3960 psi
|
Maximum load on cylinder 1
|
51360 lb
|
Maximum load on cylinder 2
|
49860 lb
|
Maximum load on cylinder 3
|
48150 lb
|
Compressive strength of cylinder 1
|
4090.0 psi
|
Type of fracture pattern of cylinder 1
|
2
|
Compressive strength of cylinder 2
|
3950.0 psi
|
Compressive strength of cylinder 3
|
3830 psi
|
Type of fracture pattern of cylinder 2
|
2
|
Type of fracture pattern of cylinder 3
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Age of specimen
|
no data0 days
|
Age of specimen in hours
|
no data0 hours
|
Serial number of delivery ticket, if available
|
no data
|