Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994330 DEA: 09366404 EFIS: 0916000006
QA Service Level: 1
DIST-CO-RTE-PM: 09-MNO-395-58.2/60.4
Work Description: HOT MIX ASPHALT (TYPE A), IMPORTED BORROW, AND ROADWAY EXCAVATION.
Location Description: MONO COUNTY ABOUT 6 MILES NORTH OF LEE VINING FROM ROUTE 167 TO 0.4 MILE NORTH OF CONWAY RANCH ROAD
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 500 South Main Street, Bishop, CA 93514
Resident Engineer: David Carruba Structure Rep.: Unknown
DIME Sample ID: 2023-08-09-39
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 08/09/2023
Date that the sample was received by the laboratory/organization performing the testing: 08/11/2023
The quantity of what the sample constitutes: 8 (4x8) Cylinders
A brief description of the sample: 6000 PSI Concrete
From where was the sample collected: Job Site
Laboratory sample identification: Conc-02
Structure unique identifier:
Structure name: Hwy 395 / Hwy 167 - Manhole Lid
The fabricator/manufacturer/facility name: Mammoth Ready Mix
The concrete mix design number: 1304-18-25-ADVA-6000
The truck number from where the sample was collected: 75
The batch plant ticket number from where the sample was collected: 54649
Concrete batch plant:
The fabricator/manufacturer designation for the sample: Manhole Lid
A detailed description of where the material sample was collected: Load 1
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2023-08-09-39-1
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/06/2023
Date Tested: 09/06/2023
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: PCC-01
28 Day Break
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
8490 psi
|
|
Maximum load on cylinder 1
|
106370 lb
|
|
Maximum load on cylinder 2
|
107220 lb
|
|
Maximum load on cylinder 3
|
106690 lb
|
|
Compressive strength of cylinder 1
|
8462.2 psi
|
|
Type of fracture pattern of cylinder 1
|
1
|
|
Compressive strength of cylinder 2
|
8529.8 psi
|
|
Compressive strength of cylinder 3
|
8487.7 psi
|
|
Type of fracture pattern of cylinder 2
|
1
|
|
Type of fracture pattern of cylinder 3
|
1
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
7 days
|
|
Age of specimen in hours
|
no data0 hours
|