Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 995072 DEA: 051P7004 EFIS: 0522000097
QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO-58-45.0/51.0
Work Description: Partial depth recycling with RHMA-G overlay.
Location Description: ON STATE HIGHWAY IN SAN LUIS OBISPO COUNTY ABOUT 22 MILES WEST OF MCKITTRICK FROM 0.2 MILE WEST OF SODA LAKE ROAD TO 0.3 MILE EAST OF BOULDER CREEK ROAD.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2023-07-13-59
TL Number from the TL Form: C991758
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Dispute Resolution
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/13/2023
Date that the sample was received by the laboratory/organization performing the testing: 07/28/2023
The quantity of what the sample constitutes: 1 Box
A brief description of the sample: 3/4 RHMA-G
From where was the sample collected: Source
Laboratory sample identification: 023-041
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Griffith Edmonston
DIME Test ID: 2023-07-13-59-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/08/2023
Date Tested: 08/07/2023
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
What temperature unit is used?
|
Celsius
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
2097.6 g
|
Corrected Asphalt Binder Content
|
8.28 %
|
Mass Loss
|
183.9 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.32 %
|
Moisture Content
|
0.00 %
|
Temperature Compensation Factor
|
0.17 %
|
Test Temperature
|
538 C
|