Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994399 DEA: 09378704 EFIS: 0919000001
QA Service Level: 1
DIST-CO-RTE-PM: 09-MNO-395-55.5/58.2
Work Description: PARTIAL DEPTH RECYCLE AND HMA (TYPE A).
Location Description: MONO COUNTY NEAR LEE VINING FROM 0.2 MILE SOUTH OF CEMETERY ROAD TO ROUTE 167
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: Unknown
Resident Engineer: David Carruba Structure Rep.: Unknown
DIME Sample ID: 2023-08-03-37
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/03/2023
Date that the sample was received by the laboratory/organization performing the testing: 08/04/2023
The quantity of what the sample constitutes: 4 Boxes for (750 - 1500) Tons
A brief description of the sample: 3/4" HMA
From where was the sample collected: Source
Laboratory sample identification: HMA-18
Structure unique identifier:
Structure name: Hwy 395 / Cemetery Rd
The fabricator/manufacturer/facility name: Granite Lee Vining
DIME Test ID: 2023-08-03-37-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/10/2023
Date Tested: 08/07/2023
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-18
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Air
|
Method Performed
|
Mechanical Agitation - Method A
|
Mass of container filled with water 1
|
7,310.5 grams
|
Mass of oven-dry sample in air for Sample 1
|
2,051.4 grams
|
Mass of container filled with the sample and water for Sample 1
|
8,525.6 grams
|
Temperature of Water
|
77.3 °F
|
Specific Gravity for Sample 1
|
2.453
|
Theoretical maximum density at 25°C (77°F)
|
152.7 lb/ft^3
|
DIME Test ID: 2023-08-03-37-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/10/2023
Date Tested: 08/07/2023
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-18
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Celsius
|
Test procedure used?
|
Method A
|
Mass of the specimen basket assembly
|
4,242.8 g
|
Mass of the specimen and specimen basket assembly prior to ignition
|
6,334.1 g
|
Mass of HMA Sample prior to ignition
|
2,091.3 g
|
Corrected Asphalt Binder Content
|
4.94 %
|
Mass Loss
|
107.7 g
|
Mass of aggregate remaining after ignition
|
1,983.6 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.21 %
|
Moisture Content
|
0.00 %
|
Temperature Compensation Factor
|
0.00 %
|
Test Temperature
|
538 C
|