Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994119 DEA: 033H3904 EFIS: 0317000340
QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC-5-22.4
Work Description: STRUCTURAL STEEL BRIDGE AND PRESTRESS STEEL GIRDERS.
Location Description: SACRAMENTO COUNTY IN SACRAMENTO AT THE SOUTH CONNECTOR UNDERCROSSING (BRIDGE NO. 24-0267)
Contractor Name: Golden State Bridge
Contractor Address: 3701 Mallard Drive, Benicia, CA 94510
Resident Engineer: Hani Eissa Structure Rep.: Delia Muñoz
DIME Sample ID: 2023-07-26-8
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/26/2023
Date that the sample was received by the laboratory/organization performing the testing: 07/28/2023
The quantity of what the sample constitutes: 20,408
A brief description of the sample: 3/4 F436 Washers
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CK Johnson Industries
Rocap Number(s):
Heat Number(s): 119491
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s): E2998
Bolt Specification: NA
Bolt Length(s):
Nut Specification: NA
Washer Specification: ASTM F436
Finish: HDG
Diameter/Size: 3/4
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s):
DIME Test ID: 2023-07-26-8-1
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/01/2023
Date Tested: 08/01/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E2998
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
P F436
|
|
Size
|
.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3.14 mils
|
DIME Test ID: 2023-07-26-8-2
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/01/2023
Date Tested: 08/01/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E2998
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
P F436
|
|
Size
|
.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.51 mils
|
DIME Test ID: 2023-07-26-8-3
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/01/2023
Date Tested: 08/01/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E2998
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
P F436
|
|
Size
|
.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3.34 mils
|
DIME Test ID: 2023-07-26-8-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/01/2023
Date Tested: 08/01/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1D
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E2998
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
P F436
|
|
Size
|
.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3.05 mils
|
DIME Test ID: 2023-07-26-8-5
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/01/2023
Date Tested: 08/01/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E2998
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
P F436
|
|
Size
|
.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
37.7
|
|
Spacing
|
Ok
|
DIME Test ID: 2023-07-26-8-6
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/01/2023
Date Tested: 08/01/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E2998
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
P F436
|
|
Size
|
.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
39.25
|
|
Spacing
|
Ok
|
DIME Test ID: 2023-07-26-8-7
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/01/2023
Date Tested: 08/01/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E2998
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
P F436
|
|
Size
|
.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
37.45
|
|
Spacing
|
Ok
|
DIME Test ID: 2023-07-26-8-8
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/01/2023
Date Tested: 08/01/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1D
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E2998
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
P F436
|
|
Size
|
.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
39.4
|
|
Spacing
|
Ok
|