Print Report | Back to Sample Detail

Sample Record for 2023-07-14-31

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994613 DEA: 112N1444 EFIS: 1122000009 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-52,125,805-VAR
Work Description: POLYESTER CONCRETE OVERLAY, METHACRYLATE, & JOINT SEALS.
Location Description: SAN DIEGO COUNTY AT VARIOUS LOCATIONS
Contractor Name: TRUESDELL CORPORATION OF CALIFORNIA, INC.
Contractor Address: 1310 W. 23rd St., Tempe, AZ 85282
Resident Engineer: Benjamin Haney Structure Rep.: Carlos Guzman

Sample Information

DIME Sample ID: 2023-07-14-31
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 07/14/2023
Date that the sample was received by the laboratory/organization performing the testing: 07/17/2023
The quantity of what the sample constitutes: 2 tankers
A brief description of the sample: 1 gallon can
From where was the sample collected: Source
Laboratory sample identification: 943815
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia

Material Information

Mfg. Lot Number(s): 1480880
Batch number: 1480880
Mix number: 1480880

Test Results

Test 1 of 6

DIME Test ID: 2023-07-14-31-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 10/18/2023
Date Tested: 07/28/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Viscosity 109

Test 2 of 6

DIME Test ID: 2023-07-14-31-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 10/18/2023
Date Tested: 07/28/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Density Units pounds/gallons
Liquid Density (pounds per gallon) 9

Test 3 of 6

DIME Test ID: 2023-07-14-31-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 10/18/2023
Date Tested: 07/20/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted vendor's results.
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested 6
Conditioning procedure 18/25/50+5/70
Speed of testing 0.45 in/min
Sample 1 Width 0.486 in
Sample 1 Ultimate strength 3399.1 psi
Sample 1 Thickness 0.267 in
Sample 1 Area 0.1298 in^2
Sample 1 Ultimate Strength Actual 441.2 lbs
Sample 1 percent elongation 64.9 %
Sample 1 Time no data0 MM:SS
Sample 2 Width 0.486 in
Sample 2 Thickness 0.262 in
Sample 2 Area 0.1273 in^2
Sample 2 Ultimate strength 3428.1 psi
Sample 2 Ultimate Strength Actual 436.4 lbs
Sample 2 percent elongation 63 %
Sample 2 Time no data0 MM:SS
Sample 3 Width 0.487 in
Sample 3 Thickness 0.255 in
Sample 3 Area 0.1242 in^2
Sample 3 Ultimate strength 3450.1 psi
Sample 3 Ultimate Strength Actual 428.5 lbs
Sample 3 percent elongation 64.2 %
Sample 3 Time no data0 MM:SS
Sample 4 Width 0.487 in
Sample 4 Thickness 0.253 in
Sample 4 Area 0.1232 in^2
Sample 4 Ultimate strength 3447.2 psi
Sample 4 Ultimate Strength Actual 424.7 lbs
Sample 4 percent elongation 62.5 %
Sample 4 Time no data0 MM:SS
Sample 5 Width 0.488 in
Sample 5 Thickness 0.255 in
Sample 5 Area 0.1244 in^2
Sample 5 Ultimate strength 3536.2 psi
Sample 5 Ultimate Strength Actual 439.9 lbs
Sample 5 percent elongation 66.5 %
Sample 5 Time no data0 MM:SS
Sample 6 Width 0.486 in
Sample 6 Thickness 0.259 in
Sample 6 Area 0.1259 in^2
Sample 6 Ultimate strength 3477.4 psi
Sample 6 Ultimate Strength Actual 437.8 lbs
Sample 6 percent elongation 64.8 %
Sample 6 Time no data0 MM:SS
Ultimate Strength Average 3456 psi
Percent Elongation Average 64 %

Test 4 of 6

DIME Test ID: 2023-07-14-31-4
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 10/18/2023
Date Tested: 07/21/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted vendor's results.
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1 24hr
Maximum applied load (P) for Sample 1 1595 lb
Span length for Sample 1 9 in
Break location for Sample 1 bond
Specimen defects/notes for Sample 1 no data
Surface type for Sample 1 SSD
Modulus of rupture (R) for Sample 1 797.5 psi
Curing history for Sample 2 24hr
Maximum applied load (P) for Sample 2 1562 lb
Span length for Sample 2 9 in
Break location for Sample 2 bond
Specimen defects/notes for Sample 2 no data
Surface type for Sample 2 SSD
Modulus of rupture (R) for Sample 2 781 psi
Curing history for Sample 3 24hr
Maximum applied load (P) for Sample 3 1702.4 lb
Span length for Sample 3 9 in
Break location for Sample 3 bond
Specimen defects/notes for Sample 3 no data
Surface type for Sample 3 SSD
Modulus of rupture (R) for Sample 3 851.2 psi

Test 5 of 6

DIME Test ID: 2023-07-14-31-5
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 10/18/2023
Date Tested: 07/18/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted vendor's results.
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid 153.9 mm
Room Temperature 77 f
Tare weight no data
Initial weight 100.07 grams
Weight at 5 minutes 99.967 grams
Weight at 10 minutes 99.894 grams
Weight at 15 minutes 99.823 grams
Weight at 20 minutes 99.755 grams
Weight at 25 minutes 99.685 grams
Weight at 30 minutes 99.62 grams
Final weight 99.62 grams
Total weight loss 0.45 grams
Calculated radius of gallon can lid in cm 7.695 cm
Lid Factor 53.757 m^2
Volatile emission 24.191 grams/m^2

Test 6 of 6

DIME Test ID: 2023-07-14-31-6
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 10/18/2023
Date Tested: 07/28/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination 45.6