Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993844 DEA: 070W1004 EFIS: 0721000043
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-31.8/42.6
Work Description: PLACE RUBBERIZED HMA (GAP GRADED)
Location Description: LOS ANGELES COUNTY IN BURBANK AND LOS ANGELES FROM COHASSET STREET UNDERCROSSING TO ROXFORD STREET UNDERCROSSING
Contractor Name: C. A. RASMUSSEN INC
Contractor Address: 28548 LIVINGSTON AVE, VALENCIA, CA 91355
Resident Engineer: Sam Toutounchian Structure Rep.: Unknown
DIME Sample ID: 2023-07-14-29
TL Number from the TL Form: 019557
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/14/2023
Date that the sample was received by the laboratory/organization performing the testing: 07/17/2023
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 3/4" RHMA-G 226108 SVA3 LTR
From where was the sample collected: Manufacturer
Laboratory sample identification: 23-261
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Materials Sun Valley
DIME Test ID: 2023-07-14-29-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/21/2023
Date Tested: 07/19/2023
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of Samples
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Air
|
Method Performed
|
Mechanical Agitation - Method A
|
Mass of container filled with water 1
|
7359.3 grams
|
Mass of oven-dry sample in air for Sample 1
|
2528.3 grams
|
Mass of container filled with the sample and water for Sample 1
|
8853.7 grams
|
Temperature of Water
|
77 °F
|
Specific Gravity for Sample 1
|
2.445
|
Theoretical maximum density at 25°C (77°F)
|
152.2 lb/ft^3
|
DIME Test ID: 2023-07-14-29-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/21/2023
Date Tested: 07/19/2023
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Celsius
|
Test procedure used?
|
Method A
|
Mass of the specimen basket assembly
|
4024.0 g
|
Mass of the specimen and specimen basket assembly prior to ignition
|
6348.9 g
|
Mass of HMA Sample prior to ignition
|
2324.9 g
|
Corrected Asphalt Binder Content
|
7.38 %
|
Mass Loss
|
179.0 g
|
Mass of aggregate remaining after ignition
|
2145.9 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.32 %
|
Moisture Content
|
0.00 %
|
Temperature Compensation Factor
|
0.00 %
|
Test Temperature
|
538 C
|