Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 208967 DEA: 110223U4 EFIS: 1112000102
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-5,89-R29.1/R30.5
Work Description: REPLACE AND WIDEN BRIDGE, RECONSTRUCT RAMPS AND INTERSECTION.
Location Description: SAN DIEGO COUNTY IN SAN DIEGO FROM 0.4 MILE SOUTH OF GENESEE AVENUE OVERCROSSING TO SORRENTO VIADUCT
Contractor Name: Flatiron
Contractor Address: 1770 LA COSTA MEADOWS DRIVE, SAN MARCOS CA 92078
Resident Engineer: Dave Pound Structure Rep.: Anh Ma
DIME Sample ID: 2016-01-08-4
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 01/08/2016
Date that the sample was received by the laboratory/organization performing the testing: 01/13/2016
The quantity of what the sample constitutes: 1
A brief description of the sample: Coupon Casting
From where was the sample collected: Distributor
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: BCI
Heat Number (s): 11175, 11195
Part Number (s): 6827216246
Material Specification: A536
Grades: 65-45-12
Metal Foundry Manufacturer (Mill): BCI
Prestressing Manufacturer: DSI
DIME Test ID: 2016-01-08-4-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 01/14/2016
Date Tested: 01/13/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
Number of Samples
|
2
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | | 11175 | 0.495 | 0.1924 | 60822 | 103790 | 8.6 | Fred | | 11195 | 0.495 | 0.1924 | 65346 | 113150 | 8.6 | Fred |
| |
UTM
|
67KIP
|
Temperature
|
72 F
|