Sample Record for 2023-07-14-10

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214486 DEA: 080K1224 EFIS: 0815000244 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-R28.6/37.5
Work Description: REHBILIATATE EXISTING MAINLINE AND RAMP PAVEMENT
Location Description: SAN BERNARDINO COUNTY IN HESPERIA AND VICTORVILLE FROM OAK HILL ROAD OVERCROSSING TO 0.1 MILE SOUTH OF BEAR VALLEY ROAD OVERCROSSING
Contractor Name: SULLY - MILLER CONTRACTING COMPANY
Contractor Address: 135 S STATE COLLEGE BLVD. 400, BREA, CA 92821
Resident Engineer: Larry J Canuti Structure Rep.: Taghreed Al-khateeb

Sample Information

DIME Sample ID: 2023-07-14-10
TL Number from the TL Form: 714
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/14/2023
Date that the sample was received by the laboratory/organization performing the testing: 07/16/2023
The quantity of what the sample constitutes: 6
A brief description of the sample: 6X12
From where was the sample collected: Job Site
Laboratory sample identification: 1042-714
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: SULLY Miller

Material Information

The concrete mix design number: G3-22-PCC-273
The truck number from where the sample was collected: Not Provided on TL
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: NA
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2023-07-14-10-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617 - Sulfur Mortar Cap
Cured in accordance with ASTM C511
Verified Date: 08/30/2023
Date Tested: 08/25/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Cross sectional area of cylinder 1 28.09 in^2
Cross sectional area of cylinder 2 28.09 in^2
Cross sectional area of cylinder 3 28.18 in^2
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Compressive strength (to nearest 10 psi) 4240 psi
Average diameter of cylinder 1 5.98 in
Average diameter of cylinder 2 5.98 in
Compressive strength of cylinder 1 4317.4 psi
Compressive strength of cylinder 2 4248.3 psi
Average diameter of cylinder 3 5.99 in
Compressive strength of cylinder 3 4151.3 psi
Maximum load on cylinder 1 121275 lb
Maximum load on cylinder 2 119335 lb
Maximum load on cylinder 3 116985 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 42 days

Test 2 of 2

DIME Test ID: 2023-07-14-10-2
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 11/14/2023
Date Tested: 10/12/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? no data
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 5.98 in
Average diameter of cylinder 2 5.99 in
Average diameter of cylinder 3 5.99 in
Cross sectional area of cylinder 1 28.09 in^2
Cross sectional area of cylinder 2 28.18 in^2
Cross sectional area of cylinder 3 28.18 in^2
Compressive strength (to nearest 10 psi) 4900 psi
Maximum load on cylinder 1 137840 lb
Maximum load on cylinder 2 138990 lb
Maximum load on cylinder 3 137315 lb
Compressive strength of cylinder 1 4910.0 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 4930.0 psi
Compressive strength of cylinder 3 4870 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen no data0 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data