Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993703 DEA: 070W0404 EFIS: 0721000028 MINOR: 11A3471
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-90-0.9/T3.3
Work Description: PCC GRINDING, SLAB REPLACEMENT, SLURRY SEAL & COLD PLANE AC PAVEMENT.
Location Description: LOS ANGELES COUNTY IN LOS ANGELES AND CULVER CITY FROM ROUTE 1 TO SLAUSON AVENUE
Contractor Name: AUTOBAHN CONSTRUCTION
Contractor Address: 933 N Batavia St,, Orange, CA 92867
Resident Engineer: Frank Shin Structure Rep.: Unknown
DIME Sample ID: 2023-07-08-5
TL Number from the TL Form: 0708A2
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/08/2023
Date that the sample was received by the laboratory/organization performing the testing: 07/10/2023
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 1/2" RHMA-G 326120M IRW LTR
From where was the sample collected: Manufacturer
Laboratory sample identification: 23-245
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Materials Irwindale
DIME Test ID: 2023-07-08-5-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/11/2023
Date Tested: 07/11/2023
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7359.3 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1517.4 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8251.3 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.426
|
|
Theoretical maximum density at 25°C (77°F)
|
151 lb/ft^3
|
DIME Test ID: 2023-07-08-5-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/11/2023
Date Tested: 07/11/2023
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4007.1 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5512.6 g
|
|
Mass of HMA Sample prior to ignition
|
1505.5 g
|
|
Corrected Asphalt Binder Content
|
7.52 %
|
|
Mass Loss
|
115.8 g
|
|
Mass of aggregate remaining after ignition
|
1389.7 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.17 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|