Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993318 DEA: 11423704 EFIS: 1116000059
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-8-R31.8/R41.7
Work Description: PLACE CRCP, HMA, MGS, AND WATER POLLUTION CONTROL SYSTEM.
Location Description: SAN DIEGO COUNTY NEAR ALPINE FROM VIEJAS CREEK BRIDGE TO PINE VALLEY CREEK BRIDGE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5860 El Camino Real, Ste 200, Carlsbad, CA 92008
Resident Engineer: Art Pannu Structure Rep.: Carlos Guzman
DIME Sample ID: 2023-06-29-35
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/29/2023
Date that the sample was received by the laboratory/organization performing the testing: 06/29/2023
The quantity of what the sample constitutes: 12 boxes 3 bags
A brief description of the sample: 1/2" HMA-A
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marrieta
DIME Test ID: 2023-06-29-35-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/03/2023
Date Tested: 08/16/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Fahrenheit
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4009.4 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5548.5 g
|
|
Mass of HMA Sample prior to ignition
|
1539.1 g
|
|
Corrected Asphalt Binder Content
|
5.14 %
|
|
Mass Loss
|
91.7 g
|
|
Mass of aggregate remaining after ignition
|
1447.4 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.82 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 F
|
DIME Test ID: 2023-06-29-35-2
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 10/03/2023
Date Tested: 07/18/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7477.1 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1570.9 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8409.5 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.46
|
|
Theoretical maximum density at 25°C (77°F)
|
153.1 lb/ft^3
|
DIME Test ID: 2023-06-29-35-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 10/03/2023
Date Tested: 07/18/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
3.8 %
|
|
Percent Air Voids 2
|
3.5 %
|
|
Percent Air Voids 3
|
3.6 %
|
|
Average Percent Air Voids
|
3.6 %
|
DIME Test ID: 2023-06-29-35-4
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 10/03/2023
Date Tested: 07/18/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.366
|
|
Bulk Specific Gravity 2
|
2.373
|
|
Bulk Specific Gravity 3
|
2.372
|
|
Average Bulk Specific Gravity
|
2.37
|
DIME Test ID: 2023-06-29-35-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 10/03/2023
Date Tested: 07/21/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
196 psi
|
|
Average Wet Tensile Strength
|
139 psi
|
|
Tensile Strength Ratio
|
0.71
|
DIME Test ID: 2023-06-29-35-6
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 10/03/2023
Date Tested: 07/21/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Specimen Preparation Method
|
no data
|
|
Test Temperature
|
122 F
|
|
Air Void Content for specimen A-1
|
no data
|
|
Air Void Content for specimen A-2
|
no data
|
|
Air Void Content for specimen B-1
|
no data
|
|
Air Void Content for specimen B-2
|
no data
|
|
Stripping Inflection Point (Wheel A)
|
>15000
|
|
Stripping Inflection Point (Wheel B)
|
>15000
|
|
Maximum impression at 5000 passes (left wheel)
|
1.65 mm
|
|
Maximum impression at 5000 passes (right wheel)
|
1.6 mm
|
|
Average impression at 5000 passes (left/right avg)
|
1.63 mm
|
|
Maximum impression at 10000 passes (left wheel)
|
1.97 mm
|
|
Maximum impression at 10000 passes (right wheel)
|
1.92 mm
|
|
Average impression at 10000 passes (left/right avg)
|
1.94 mm
|
|
Maximum impression at 15000 passes (left wheel)
|
2.22 mm
|
|
Maximum impression at 15000 passes (right wheel)
|
2.14 mm
|
|
Average impression at 15000 passes (left/right avg)
|
2.18 mm
|
|
Average impression at 20000 passes (left/right avg)
|
2.44 mm
|
|
Average impression at 25000 passes (left/right avg)
|
no data
|
DIME Test ID: 2023-06-29-35-7
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/03/2023
Date Tested: 07/18/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 3 RAP Burns
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Fahrenheit
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4027.3 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5509.8 g
|
|
Mass of HMA Sample prior to ignition
|
1482.5 g
|
|
Corrected Asphalt Binder Content
|
6.62 %
|
|
Mass Loss
|
98.1 g
|
|
Mass of aggregate remaining after ignition
|
1384.4 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data0 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 F
|
DIME Test ID: 2023-06-29-35-8
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 10/03/2023
Date Tested: 08/18/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: RAP Rice
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7477.1 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1536 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8379.7 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.425
|
|
Theoretical maximum density at 25°C (77°F)
|
150.9 lb/ft^3
|