Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214336 DEA: 07302404 EFIS: 0713000488
QA Service Level: 1
DIST-CO-RTE-PM: 07-VEN-101-37/40
Work Description: PADRE JUAN REHAB
Location Description: VEN 101
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 4820 McGrath Street, Suite 101, Ventura, CA 93003
Resident Engineer: Alfred Ira Structure Rep.: Unknown
DIME Sample ID: 2023-06-29-33
TL Number from the TL Form:
Sample Submitted By Organization: Alta Vista Solutions - Whittier
Sample Organization Contact: (510) 542-9827
Type of Sample: Quality Assurance
Type of Material: Soil
Sample Taken Date: 06/29/2023
Date that the sample was received by the laboratory/organization performing the testing: 06/29/2023
The quantity of what the sample constitutes: 11960 sqft
A brief description of the sample: Native Soil - Subgrade
From where was the sample collected: Job Site
Laboratory sample identification: 23-0945
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: n/a
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: CTM 231 Test Holes
Where the material sample would have been placed if not sampled:
DIME Test ID: 2023-06-29-33-1
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Verified Date: 07/07/2023
Date Tested: 06/29/2023
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Standard Count Density
|
10059 g/cc
|
Count or Density 1
|
15860 g/cc
|
Count or Density 2
|
18015 g/cc
|
Count or Density 3
|
14985 g/cc
|
Count or Density 4
|
15485 g/cc
|
Count or Density 5
|
15108 g/cc
|
Standard Count Moisture
|
15630 g/cc
|
Moisture Count 1
|
4012 g/cc
|
Moisture Count 2
|
3639 g/cc
|
Moisture Count 3
|
4143 g/cc
|
Moisture Count 4
|
2070 g/cc
|
Moisture Count 5
|
3399 g/cc
|
Sum of Count or Density
|
79453 g/cc
|
Average of Count or Density
|
15891 g/cc
|
Sum of Moisture Count
|
17263 g/cc
|
Average of Moisture Count
|
3453 g/cc
|
Count Ratio Density
|
1.58
|
Count Ratio Moisture
|
0.22
|
Calculated Percent Relative Compaction
|
98.2 %
|
Reported Percent Relative Compaction
|
98 %
|
DIME Test ID: 2023-06-29-33-2
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Verified Date: 07/07/2023
Date Tested: 06/29/2023
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is oversize material
|
No
|
In-place wet density
|
2.14
|
Highest adjust wet density
|
2.18
|
Relative compaction
|
98
|
% Moisture
|
9.2 %
|
Optimum Moisture
|
11.2 %
|