Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 043Y6404 Cty MRN Rte 101 PM 24.01/24.01 Vendor # |
|
REPORT OF LABORATORY TESTING |
||||
|
Resident Engineer: |
Fabio La serna |
Date Reported: |
11/13/2023 |
|
|
Address: |
TL Number: |
|
||
|
City: |
||||
|
Project Name: |
||||
|
Prime Contractor: Ghilotti Construction Company |
||||
|
Sample Taken Date: |
07/06/2023 |
Mix Design: |
SL-4700CG |
|
|
Contractor: Unknown |
Location : |
|||
|
Structure unique identifier: |
||||
|
Structure name: San Antonio Blvd - Emergency Soldier Pile Wall |
||||
|
Location of Pour: Piles 23 25 and 27 |
||||
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.03 | 12.76 | 114471 | 8974.0 | 1 |
| 2 | 4.03 | 12.76 | 111919 | 8774.0 | 1 |
| 3 | 4.02 | 12.69 | 115271 | 9082 | 1 |
DIME Test ID: 2023-07-06-11-4
Number of specimens: 3
Compressive strength (to nearest 10 psi): 8940
Age of specimen: 28 days
Certified By: Spencer Adams
ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
| Temperature |
|---|
| 81 |
DIME Test ID: 2023-07-06-11-5
Certified By: Philip Latasa
ASTM C143-15a: Standard Test Method for Slump of Hydraulic-Cement Concrete
| Slump |
|---|
| 7.25 |
DIME Test ID: 2023-07-06-11-6
Certified By: Philip Latasa
|
*Subject to final inspection by the Resident Engineer. |
|
TL- Report of Laboratory Testing