Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215677 DEA: 044G0804 EFIS: 0412000332 COOP: 042676
QA Service Level: 1
DIST-CO-RTE-PM: 04-SOL-80-R10.4/30.2
Work Description: Highway widening, overhead signs, and electronic toll system.
Location Description: In Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing.
Contractor Name: O.C. JONES & SONS, INC.
Contractor Address: 1520 Fourth Street, Berkeley, CA 94710
Resident Engineer: Justen Tatum Structure Rep.: Kelsey Littell
DIME Sample ID: 2023-06-12-52
TL Number from the TL Form: 051720
Sample Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Sample Organization Contact: (916) 206-4373
Type of Sample: Quality Assurance
Type of Material: Concrete Core
Sample Taken Date: 06/12/2023
Date that the sample was received by the laboratory/organization performing the testing: 06/26/2023
The quantity of what the sample constitutes: 3 Cores
A brief description of the sample: 3x6 Shotcrete Core
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: Slope Paving
The fabricator/manufacturer/facility name: Bridgeway
Detail description: Shotcrete
Structure names: Slope Paving
Type of material: Shotcrete
DIME Test ID: 2023-06-12-52-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 06/27/2023
Date Tested: 06/27/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617/CTM521
|
|
Average diameter of cylinder 1
|
2.78 in
|
|
Average diameter of cylinder 2
|
2.79 in
|
|
Average diameter of cylinder 3
|
2.80 in
|
|
Cross sectional area of cylinder 1
|
6.07 in^2
|
|
Cross sectional area of cylinder 2
|
6.11 in^2
|
|
Cross sectional area of cylinder 3
|
6.16 in^2
|
|
Compressive strength (to nearest 10 psi)
|
4750 psi
|
|
Maximum load on cylinder 1
|
23808 lbf
|
|
Maximum load on cylinder 2
|
33793 lbf
|
|
Maximum load on cylinder 3
|
29623 lbf
|
|
Compressive strength of cylinder 1
|
3922.0 psi
|
|
Type of fracture pattern of cylinder 1
|
4
|
|
Compressive strength of cylinder 2
|
5527.0 psi
|
|
Compressive strength of cylinder 3
|
4811 psi
|
|
Type of fracture pattern of cylinder 2
|
4
|
|
Type of fracture pattern of cylinder 3
|
4
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
7 days
|
|
Age of specimen in hours
|
no data
|