Sample Record for 2015-11-21-3
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 209511 DEA: 080Q7403 EFIS: 0800020456
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-15.4/30.8
Work Description: Design Build project provides pavement rehabilitation (including ramps) on I-15 near Cajon Pass, CA.
Location Description: On I-15 from 0.4 mile north of Kenwood Avenue to 0.3 mile south of West Hesperia OH
Contractor Name: Coffman Specialties, Inc./Parsons Transportation Group, Inc
Contractor Address: 9685 VIA EXCELENCIA, SUITE 200, SAN DIEGO, CA 92126
Resident Engineer: Maged Youssef Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2015-11-21-3
TL Number from the TL Form: 1121
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 11/21/2015
Date that the sample was received by the laboratory/organization performing the testing: 11/24/2015
The quantity of what the sample constitutes: 2
A brief description of the sample: 6X12
From where was the sample collected: Job Site
Laboratory sample identification: 878-21
Structure unique identifier: SBD I15PM R 15 4 30 8
Structure name: SEG1 SB LANE2 STA 142 10
The fabricator/manufacturer/facility name: CEMEX
Material Information
The concrete mix design number: 1202-8 LCB
The truck number from where the sample was collected: 65
The batch plant ticket number from where the sample was collected: 15
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: LOAD 15
Where the material sample would have been placed if not sampled: Unknown
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 1
DIME Test ID: 2015-11-21-3-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 11/24/2015
Date Tested: 11/24/2015
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
5.98 in
|
Average diameter of cylinder 2
|
5.98 in
|
Cross sectional area of cylinder 1
|
28.09 in^2
|
Cross sectional area of cylinder 2
|
28.09 in^2
|
Compressive strength (to nearest 10 psi)
|
310 psi
|
Maximum load on cylinder 1
|
8720 lb
|
Maximum load on cylinder 2
|
8800 lb
|
Compressive strength of cylinder 1
|
310.4 psi
|
Type of fracture pattern of cylinder 1
|
2
|
Compressive strength of cylinder 2
|
313.3 psi
|
Type of fracture pattern of cylinder 2
|
1
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
no data
|
Age of specimen
|
3 days
|
Age of specimen in hours
|
no data
|