Sample Record for 2023-06-13-55
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 993446 DEA: 120J34U4 EFIS: 1218000034
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-55,55-29.6,R6.4/10.3
Work Description: CONSTR BRIDGES, RW, SW, JPCP, HMA PVMT, DRAINAGE AND ELECT SYSTEMS.
Location Description: ORANGE COUNTY IN IRVINE, SANTA ANA, AND TUSTIN ON ROUTE 5 AT NEWPORT AVENUE UNDERCROSSING AND ON ROUTE 55 FROM 0.4 MILE NORTH OF ROUTE 55/405 SEPARATION TO 0.1 MILE SOUTH OF ROUTE 5/55 SEPARATION
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 Townsgate Road, Suite 200, Westlake Village, CA 91361
Resident Engineer: Adrian Wu Structure Rep.: Yong Gyun Park
Sample Information
DIME Sample ID: 2023-06-13-55
TL Number from the TL Form:
Sample Submitted By Organization: Con-Fab California, LLC
Sample Organization Contact: (661) 630-7162
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 06/13/2023
Date that the sample was received by the laboratory/organization performing the testing: 06/14/2023
The quantity of what the sample constitutes: Two Girder
A brief description of the sample: PCC 4'' X 8'' Test Cylinder
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Con-Fab California, LLC
Material Information
The concrete mix design number: SCC-S85-0FG
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 3566
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Back of truck chute
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 7
DIME Test ID: 2023-06-13-55-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 06/07/2024
Date Tested: 06/13/2023
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: benjamina@confabca.com
Organization Phone: (661) 630-3283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Test 2 of 7
DIME Test ID: 2023-06-13-55-3
Test Method: ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 06/07/2024
Date Tested: 06/13/2023
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: benjamina@confabca.com
Organization Phone: (661) 630-3283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Identification of concrete represented by the sample
|
I Girder
|
|
Volume of the measure
|
0.25 ft^3
|
|
Density of concrete
|
152.6 lb/ft^3
|
|
Yield of concrete
|
no data
|
|
Relative yield of the batch
|
no data
|
|
Cement content
|
no data
|
|
Air content
|
1.6 %
|
Test 3 of 7
DIME Test ID: 2023-06-13-55-4
Test Method: ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 06/07/2024
Date Tested: 06/13/2023
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: benjamina@confabca.com
Organization Phone: (661) 630-3283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Test 4 of 7
DIME Test ID: 2023-06-13-55-5
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 06/07/2024
Date Tested: 06/20/2023
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: benjamina@confabca.com
Organization Phone: (661) 630-3283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
no data
|
|
Apparent mass of submerged cylinder 1
|
1 lb
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
7720 psi
|
|
Maximum load on cylinder 1
|
98505 lb
|
|
Maximum load on cylinder 2
|
92055 lb
|
|
Maximum load on cylinder 3
|
100530 lb
|
|
Type of fracture pattern of cylinder 1
|
4
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
7 days
|
|
Age of specimen in hours
|
no data0 hours
|
|
Serial number of delivery ticket, if available
|
no data
|
Test 5 of 7
DIME Test ID: 2023-06-13-55-6
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 06/07/2024
Date Tested: 06/14/2023
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: benjamina@confabca.com
Organization Phone: (661) 630-3283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
no data
|
|
Apparent mass of submerged cylinder 1
|
1 lb
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
6710 psi
|
|
Maximum load on cylinder 1
|
85005 lb
|
|
Maximum load on cylinder 2
|
83915 lb
|
|
Maximum load on cylinder 3
|
84120 lb
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
no data0 days
|
|
Age of specimen in hours
|
14 hours
|
|
Serial number of delivery ticket, if available
|
no data
|
Test 6 of 7
DIME Test ID: 2023-06-13-55-7
Test Method: CTM TEMP1-16: Test Method for Monitoring Precast Concrete Curing Temperature (Curing temperature)
Verified Date: 06/07/2024
Date Tested: 06/13/2023
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: benjamina@confabca.com
Organization Phone: (661) 630-3283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Precast Maximum Curing Temperature
|
135 °F
|
Test 7 of 7
DIME Test ID: 2023-06-13-55-8
Test Method: ASTM C1611-21: Standard Test Method for Slump Flow of Self-Consolidating Concrete
Verified Date: 06/07/2024
Date Tested: 06/13/2023
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Avenue,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: benjamina@confabca.com
Organization Phone: (661) 630-3283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
What unit system is used for measurements?
|
inches
|
|
Slump Flow
|
25.5 in
|
|
Filling the mold procedure
|
Filling Procedure B (Inverted Mold)
|
|
Diameter 1
|
25.5 in
|
|
Diameter 2
|
25.5 in
|
|
Visual Stability Index
|
no data0
|