Print Report | Back to Sample Detail

Sample Record for 2023-06-12-31

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993234 DEA: 051H0004 EFIS: 0516000011 QA Service Level: 1
DIST-CO-RTE-PM: 05-MON-68-1.1/L4.3
Work Description: PLACE HMA AND MODIFY SIGNAL AND LIGHTING SYSTEMS.
Location Description: MONTEREY COUNTY IN AND NEAR PACIFIC GROVE AND MONTEREY FROM FOREST AVENUE TO ROUTE 68/1 SEPARATION
Contractor Name: Graniterock Company
Contractor Address: 350 Technology Drive, Watsonville, CA 95076
Resident Engineer: Tyler Lavering Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-06-12-31
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Monterey Construction Field Laboratory
Sample Organization Contact: 831-818-0254
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/12/2023
Date that the sample was received by the laboratory/organization performing the testing: 06/12/2023
The quantity of what the sample constitutes: 331.1 Tons
A brief description of the sample: 3/4 HMA Type A
From where was the sample collected: Source
Laboratory sample identification: 0612232100
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Graniterock Drum Plant

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: 1
Sublot number: 27
HMA Mix Number: 937

Test Results

Test 1 of 1

DIME Test ID: 2023-06-12-31-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/15/2023
Date Tested: 06/12/2023
Submitted By Organization: CT D05 - Monterey Construction Field Laboratory
Organization Address: 1529 Salinas Highway,
Organization City: Monterey
Organization State: CA
Organization Zipcode: 93940
Organization Email: wesley.rider@dot.ca.gov
Organization Phone: (831) 818-0254
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2056.4 g
Corrected Asphalt Binder Content 5.2 %
Mass Loss 126.2 g
Correction Factor (Percent by mass of HMA Specimen) 0.94 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 482 F