Sample Record for 2023-06-01-71
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994332 DEA: 11430444 EFIS: 1118000204
QA Service Level: 1
DIST-CO-RTE-PM: 11-IMP-8,78-Var
Work Description: REHABILITATE BRIDGES, CONCRETE BARRIERS, TERMINAL SYSTEMS, ELECTRICAL.
Location Description: IMPERIAL COUNTY AT VARIOUS LOCATIONS
Contractor Name: J. FRANCIS COMPANY
Contractor Address: 16197 Krameria Ave, Riverside, CA 92504
Resident Engineer: Karl Hartline Structure Rep.: Karl Hartline
Sample Information
DIME Sample ID: 2023-06-01-71
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 06/01/2023
Date that the sample was received by the laboratory/organization performing the testing: 06/09/2023
The quantity of what the sample constitutes: 4
A brief description of the sample: #6 Barsplice Couplers
From where was the sample collected: Job Site
Laboratory sample identification: 690956
Structure unique identifier: 58-0196R
Structure name: All American Canal Rt
The fabricator/manufacturer/facility name: BarSplice
Material Information
Production or Authorization Testing: Production Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: CMC
Coupler Manufacturer: BarSplice
Intermediate Assembler or Fabricator:
Rebar Size: #6
Coupler Model: Grip Twist
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter:
Rebar Hoop Fabricator:
Coupler Component Heat/Lot Number(s): C219745
Rebar Heat Number(s): 6035421
Rebar Size 2 :
Coupler Unique ID: SS-17-05
Test Results
Test 1 of 1
DIME Test ID: 2023-06-01-71-7
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Verified Date: 06/20/2023
Date Tested: 06/09/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
3
|
Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | 1 | 1 | 6 | 0.44 | -0.0008 | 44788 | 101792 | Ok Necking | rmacias | 2 | 1 | 6 | 0.44 | 0 | 44949 | 102156 | Ok Necking | rmacias | 3 | 1 | 6 | 0.44 | 0 | 44969 | 102203 | Ok Necking | rmacias |
| |
Temperature
|
72 f
|
UTM
|
400KIP
|
Halo ID
|
Small
|
Tests Assigned to this Sample
DIME Test ID | Test Method | Assigned Date | Test Date | Assigned By | Assigned Lab | Test Comments | Assigned To |
2023-06-01-71-1 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | 06/15/2023 | 06/09/2023 | Steven Paine | CT HQ - Sacramento Structural Materials Testing Laboratory | BarSplice coupler ok necking | Ruben Macias |
2023-06-01-71-2 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | 06/15/2023 | Not scheduled | Steven Paine | CT HQ - Sacramento Structural Materials Testing Laboratory | BarSplice Grip Twist necking ok | |
2023-06-01-71-3 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | 06/15/2023 | Not scheduled | Steven Paine | CT HQ - Sacramento Structural Materials Testing Laboratory | BarSplice Grip Twist necking ok | |
2023-06-01-71-4 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | 06/15/2023 | Not scheduled | Steven Paine | CT HQ - Sacramento Structural Materials Testing Laboratory | BarSplice Grip Twist necking ok | |
2023-06-01-71-5 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | 06/15/2023 | Not scheduled | Steven Paine | CT HQ - Sacramento Structural Materials Testing Laboratory | BarSplice Grip Twist necking ok | |
2023-06-01-71-6 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | 06/15/2023 | Not scheduled | Steven Paine | CT HQ - Sacramento Structural Materials Testing Laboratory | BarSplice Grip Twist necking ok | |
752637526475265752667526775268