Print Report | Back to Sample Detail

Sample Record for 2023-05-24-46

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993118 DEA: 101C3304 EFIS: 1014000146 QA Service Level: 1
DIST-CO-RTE-PM: 10-SJ-205-R4.6/R9.0
Work Description: Widening bridges, ramps and roadway. SR205 SMART CORRIDOR - PHASE 2
Location Description: On state highway in San Joaquin County in and near Tracy from Janney Overhead to 1.3 miles east of MacArthur Drive Overcrossing.
Contractor Name: Bay Cities Paving & Grading Inc.
Contractor Address: 1450 Civic Ct., Bldg B #400, Concord, CA 94520
Resident Engineer: Jim Benton Structure Rep.: Ron Matin

Sample Information

DIME Sample ID: 2023-05-24-46
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 05/24/2023
Date that the sample was received by the laboratory/organization performing the testing: 05/30/2023
The quantity of what the sample constitutes: 204
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber

Material Information

Mfg. Lot Number(s): 22678-1
Material/Compound/Elastomer ID: NA
Samples Representing: 204
Description (size): 1" x 4" x 6"
Comments:
Description (Number of Shims): 2
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: NA

Test Results

Test 1 of 4

DIME Test ID: 2023-05-24-46-1
Test Method: ASTM D2240-15r21: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 06/20/2023
Date Tested: 06/05/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 50
Reading #2 50
Reading #3 50
Reading #4 51
Reading #5 51
Mean 50.4

Test 2 of 4

DIME Test ID: 2023-05-24-46-2
Test Method: ASTM D412-16r21: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 06/20/2023
Date Tested: 06/05/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values lbf per sqr in
UTM 2kip
Humidity 50.00 %
Temperature 72 F
Sample 1 Median Thickness 0.092
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 3022.98 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.09
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2719.34 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.091
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2735.17 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2735.2 lbf/in^2

Test 3 of 4

DIME Test ID: 2023-05-24-46-3
Test Method: ASTM D624-00r20: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 06/20/2023
Date Tested: 06/05/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
UTM 2kip
Humidity 50.00 %
Temperature 72 F
Sample 1 Median Thickness 0.088
Sample 1 Tear Strength 225.8
Sample 2 Median Thickness 0.091
Sample 2 Tear Strength 230
Sample 3 Median Thickness 0.088
Sample 3 Tear Strength 219.4
Median of the Tear Strength Values 225.8 lb/in

Test 4 of 4

DIME Test ID: 2023-05-24-46-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 06/06/2023
Date Tested: 06/06/2023
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Result Pass