Print Report | Back to Sample Detail

Sample Record for 2023-04-12-46

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994787 DEA: 061F7004 EFIS: 0623000145 QA Service Level: 1
DIST-CO-RTE-PM: 06-TUL-99-4/15.5
Work Description:
Location Description:
Contractor Name: Yarbs Grading and Paving, Inc.
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-04-12-46
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Visalia Field Laboratory
Sample Organization Contact: (559) 974-1304
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/12/2023
Date that the sample was received by the laboratory/organization performing the testing: 04/13/2023
The quantity of what the sample constitutes: 161 Tons
A brief description of the sample: 3/4 HMA-A
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Porterville Rock and Recycle PAI

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 22J026
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2023-04-12-46-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/26/2023
Date Tested: 04/13/2023
Submitted By Organization: CT D06 - Visalia Field Laboratory
Organization Address: 8530 W Roosevelt Ave,
Organization City: Visalia
Organization State: CA
Organization Zipcode: 93291
Organization Email: paul.klinker@dot.ca.gov
Organization Phone: (559) 974-1304
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2065.6 g
Corrected Asphalt Binder Content 4.99 %
Mass Loss 114.2 g
Correction Factor (Percent by mass of HMA Specimen) 0.39 %
Moisture Content 0.01 %
Temperature Compensation Factor 0.15 %
Test Temperature 538 C