Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214830 DEA: 043G6304 EFIS: 0412000409
QA Service Level: 1
DIST-CO-RTE-PM: 04-SCL-4-SCl-9 -4.75/4.9
Work Description: Saratoga Creek Bridge Rehabilitation Project
Location Description: San Jose - Saratoga Creek
Contractor Name: Myers and Sons
Contractor Address: 4600 NORTHGATE BLVD, STE 100, SACRAMENTO, CA 95834
Resident Engineer: Arif Khan Structure Rep.: OANH BUI
DIME Sample ID: 2023-05-09-78
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 05/09/2023
Date that the sample was received by the laboratory/organization performing the testing: 05/17/2023
The quantity of what the sample constitutes: 1 lot of 185 bolts
A brief description of the sample: A325 HDG
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Acrow Bridge
Rocap Number(s):
Heat Number(s): 10764180
Nut Mfg. Lot Number(s): 35248-5804804202
Washer Mfg. Lot Number(s): E3141
Bolt Specification: A325
Bolt Length(s): 2.75
Nut Specification: A563
Washer Specification: F436
Finish: HDG
Diameter/Size: 3/4(10)
Bolt Mfg. Lot Number: E853G1
Rocap Test Requirement(s):
Lubricant Requirements(s):
DIME Test ID: 2023-05-09-78-1
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 06/19/2023
Date Tested: 05/22/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 1 | E853G1 | 0.7500 | 49568 | 220.49 | 10.00 | A325 Wedge Tensile | rmacias |
| |
UTM
|
450kip
|
Temperature
|
no data
|
DIME Test ID: 2023-05-09-78-2
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 06/19/2023
Date Tested: 05/22/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Proof
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 1A | | | 52895 | | Nut Proof | |
| |
UTM
|
450kip
|
Temperature
|
72 f
|
DIME Test ID: 2023-05-09-78-3
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 06/19/2023
Date Tested: 05/22/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E853G1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.75 in
|
Bolt Length
|
2.75 in
|
Pitch Diameter
|
.687 in
|
Pitch Diameter 2nd
|
.687 in
|
DIME Test ID: 2023-05-09-78-4
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 06/19/2023
Date Tested: 05/22/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E853G1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.75 in
|
Bolt Length
|
2.75 in
|
Pitch Diameter
|
.690 in
|
Pitch Diameter 2nd
|
.690 in
|
DIME Test ID: 2023-05-09-78-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/19/2023
Date Tested: 05/22/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E853G1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.75 in
|
Bolt Length
|
2.75 in
|
Measurement Average
|
3.15 mils
|
DIME Test ID: 2023-05-09-78-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/19/2023
Date Tested: 05/22/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E853G1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
.75 in
|
Bolt Length
|
2.75 in
|
Measurement Average
|
4.13 mils
|
DIME Test ID: 2023-05-09-78-7
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/19/2023
Date Tested: 05/22/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
35248-5804804202
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH U
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.63 mils
|
DIME Test ID: 2023-05-09-78-8
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/19/2023
Date Tested: 05/22/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
35248-5804804202
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH U
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.72 mils
|
DIME Test ID: 2023-05-09-78-9
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/19/2023
Date Tested: 05/22/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E3141
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.16 mils
|
DIME Test ID: 2023-05-09-78-10
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/19/2023
Date Tested: 05/22/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E3141
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
6.62 mils
|
DIME Test ID: 2023-05-09-78-11
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 06/19/2023
Date Tested: 05/22/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E3141
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
41.35
|
Spacing
|
Ok
|
DIME Test ID: 2023-05-09-78-12
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 06/19/2023
Date Tested: 05/22/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E3141
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
38.65
|
Spacing
|
Ok
|