Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994467 DEA: 101R1804 EFIS: 1023000110
QA Service Level: 1
DIST-CO-RTE-PM: 10-TUO,TUO-120-0.96, 0.96/0.96
Work Description:
Location Description:
Contractor Name: SIERRA MOUNTAIN CONSTRUCTION INC.
Contractor Address: 13919 MONO WAY, SONORA CA 95370
Resident Engineer: Troy Scheiber Structure Rep.: Unknown
DIME Sample ID: 2023-04-21-25
TL Number from the TL Form: 938462
Sample Submitted By Organization: CT D10 - District 10 Materials Laboratory
Sample Organization Contact: (209) 948-7567
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/21/2023
Date that the sample was received by the laboratory/organization performing the testing: 04/25/2023
The quantity of what the sample constitutes: 4 boxes
A brief description of the sample: 3/4 HMA
From where was the sample collected: Manufacturer
Laboratory sample identification: 23-H-61
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: GRI, Munn & Perkins
DIME Test ID: 2023-04-21-25-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 04/27/2023
Date Tested: 04/26/2023
Submitted By Organization: CT D10 - District 10 Materials Laboratory
Organization Address: 1976 East Dr. Martin Luther King Jr. Boulevard,
Organization City: Stockton
Organization State: CA
Organization Zipcode: 95205
Organization Email: mandeep.dhesi@dot.ca.gov
Organization Phone: (209) 948-7567
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Water
|
Specific Gravity for Sample 1
|
2.481
|
Theoretical maximum density at 25°C (77°F)
|
154.4 lb/ft^3
|
DIME Test ID: 2023-04-21-25-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 04/27/2023
Date Tested: 04/26/2023
Submitted By Organization: CT D10 - District 10 Materials Laboratory
Organization Address: 1976 East Dr. Martin Luther King Jr. Boulevard,
Organization City: Stockton
Organization State: CA
Organization Zipcode: 95205
Organization Email: mandeep.dhesi@dot.ca.gov
Organization Phone: (209) 948-7567
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Celsius
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
2025 g
|
Corrected Asphalt Binder Content
|
4.54 %
|
Mass Loss
|
105.3 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.51 %
|
Moisture Content
|
no data0 %
|
Temperature Compensation Factor
|
0.15 %
|
Test Temperature
|
538 C
|