Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215003 DEA: 040J6204 EFIS: 0414000019
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-680-12.4/21.9
Work Description: REHABILITATE PAVEMENT - RPL APP/DEP SLABS, 14 BRIDGES
Location Description: ALAMEDA COUNTY AT SUNOL AND IN PLEASANTON AND DUBLIN FROM KOOPMANN ROAD UNDERCROSSING TO ALAMEDA COUNTY LINE
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 Townsgate Road, Suite 200, Westlake Village, CA 91361
Resident Engineer: Eddie Dike Structure Rep.: Betty Geng
DIME Sample ID: 2023-04-04-39
TL Number from the TL Form: C369722
Sample Submitted By Organization: CT D04 - Hayward Field Laboratory
Sample Organization Contact: (510) 723-0168
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/04/2023
Date that the sample was received by the laboratory/organization performing the testing: 04/12/2023
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 3/4 HMA + 25%R
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan - Pleasanton
DIME Test ID: 2023-04-04-39-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 04/25/2023
Date Tested: 04/25/2023
Submitted By Organization: CT D04 - Hayward Field Laboratory
Organization Address: 21339 Cabot Boulevard,
Organization City: Hayward
Organization State: CA
Organization Zipcode: 94545
Organization Email: pamela.brown@dot.ca.gov
Organization Phone: (510) 385-8258
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Fahrenheit
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3021 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5138.2 g
|
|
Mass of HMA Sample prior to ignition
|
2117.2 g
|
|
Corrected Asphalt Binder Content
|
4.36 %
|
|
Mass Loss
|
116.4 g
|
|
Mass of aggregate remaining after ignition
|
2000.8 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
1 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.14 %
|
|
Test Temperature
|
482 F
|