Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215348 DEA: 060U4204 EFIS: 0616000004
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-99-R4.9/11.6
Work Description: CONSTRUCT CRCP, PLACE HMA, AND ROADWAY EXCAVATION.
Location Description: FRESNO COUNTY IN AND NEAR SELMA AND FOWLER FROM MCCALL AVENUE UNDERCROSSING TO 0.5 MILE NORTH OF MERCED STREET UNDERCROSSING
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 Townsgate Rd. Suite 200, Westlake Village CA 91361
Resident Engineer: Chris Wilfong Structure Rep.: Unknown
DIME Sample ID: 2023-03-28-14
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 417-5341
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 03/28/2023
Date that the sample was received by the laboratory/organization performing the testing: 03/29/2023
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 3/4 HMA-A
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Ashlan
DIME Test ID: 2023-03-28-14-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 03/30/2023
Date Tested: 03/29/2023
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 3240 North Millbrook Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93726
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of the specimen basket assembly
|
2878.5 g
|
Mass of the specimen and specimen basket assembly prior to ignition
|
4943.9 g
|
Mass of HMA Sample prior to ignition
|
2065.4 g
|
Corrected Asphalt Binder Content
|
4.13 %
|
Mass Loss
|
95.5 g
|
Mass of aggregate remaining after ignition
|
1969.9 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.36 %
|
Moisture Content
|
0.00 %
|
Temperature Compensation Factor
|
0.13 %
|
Test Temperature
|
538 F
|
DIME Test ID: 2023-03-28-14-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 04/12/2023
Date Tested: 04/06/2023
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 3240 North Millbrook Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93726
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test: 1A=92.9%
1B=92.6%
1C= 91.1%
Test Result Compliance: complies
Additional Comments When Verified:
Bulk Specific Gravity
|
2.424
|
Bulk Specific Gravity 2
|
2.415
|
Bulk Specific Gravity 3
|
2.376
|
Average Bulk Specific Gravity
|
2.405
|