Sample Record for 2023-03-24-19
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 993301 DEA: 060U2804 EFIS: 0615000293
QA Service Level: 1
DIST-CO-RTE-PM: 06-TUL-245-1.4,4.2
Work Description: PRECAST PRESTRESSED CONCRETE BOX GIRDER AND SLAB, BRIDGE REMOVAL.
Location Description: TULARE COUNTY NEAR WOODLAKE AT YOKOHL CREEK BRIDGE AND AT KAWEAH RIVER BRIDGE
Contractor Name: MCM Construction
Contractor Address: PO Box 620, North Highlands, Ca 95660
Resident Engineer: Mike Garrett Structure Rep.: Benajamin Holton
Sample Information
DIME Sample ID: 2023-03-24-19
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Visalia Field Laboratory
Sample Organization Contact: (559) 974-1304
Type of Sample: Quality Assurance
Type of Material: Aggregate
Sample Taken Date: 03/24/2023
Date that the sample was received by the laboratory/organization performing the testing: 03/24/2023
The quantity of what the sample constitutes: 147 tons
A brief description of the sample: HMA 3/4" PG70-10 22-J-026
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name: Kaweah- Yokohl Bridges Wood Land
The fabricator/manufacturer/facility name: Porterville Asphalt PAI
Material Information
Source Identification (SMARA, name of Pit or Job Site): Unknown
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Conveyor Belt
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number: 1
Sublot number: 3
Aggregate Mix Number: SL3
Test Results
Test 1 of 4
DIME Test ID: 2023-03-24-19-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 03/29/2023
Date Tested: 03/24/2023
Submitted By Organization: CT D06 - Visalia Field Laboratory
Organization Address: 8530 W Roosevelt Ave,
Organization City: Visalia
Organization State: CA
Organization Zipcode: 93291
Organization Email: paul.klinker@dot.ca.gov
Organization Phone: (559) 974-1304
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested?
|
Combined Gradation
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
99 %
|
Cumulative percent passing the 1/2 in. sieve
|
74 %
|
Cumulative percent passing the 3/8 in. sieve
|
65 %
|
Cumulative percent passing the #4 sieve
|
55 %
|
Cumulative percent passing the #8 sieve
|
34 %
|
Cumulative percent passing the #16 sieve
|
21 %
|
Cumulative percent passing the #30 sieve
|
14 %
|
Cumulative percent passing the #50 sieve
|
9 %
|
Cumulative percent passing the #100 sieve
|
7 %
|
Cumulative percent passing the #200 sieve
|
5.2 %
|
Test 2 of 4
DIME Test ID: 2023-03-24-19-2
Test Method: AASHTO T210-15: Standard Method of Test for Aggregate Durability Index (Durability Index)
Verified Date: 03/29/2023
Date Tested: 03/24/2023
Submitted By Organization: CT D06 - Visalia Field Laboratory
Organization Address: 8530 W Roosevelt Ave,
Organization City: Visalia
Organization State: CA
Organization Zipcode: 93291
Organization Email: paul.klinker@dot.ca.gov
Organization Phone: (559) 974-1304
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Which test procedure(s) is/are used?
|
Procedure A
|
Was strict temperature control maintained?
|
No
|
What type of water was used?
|
Distilled
|
Durability Index (coarse)
|
80
|
Test 3 of 4
DIME Test ID: 2023-03-24-19-3
Test Method: AASHTO T210-15: Standard Method of Test for Aggregate Durability Index (Durability Index)
Verified Date: 03/29/2023
Date Tested: 03/24/2023
Submitted By Organization: CT D06 - Visalia Field Laboratory
Organization Address: 8530 W Roosevelt Ave,
Organization City: Visalia
Organization State: CA
Organization Zipcode: 93291
Organization Email: paul.klinker@dot.ca.gov
Organization Phone: (559) 974-1304
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Which test procedure(s) is/are used?
|
Procedure C
|
Was strict temperature control maintained?
|
No
|
What type of water was used?
|
Distilled
|
Durability Index (coarse)
|
65
|
Test 4 of 4
DIME Test ID: 2023-03-24-19-4
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 03/29/2023
Date Tested: 03/24/2023
Submitted By Organization: CT D06 - Visalia Field Laboratory
Organization Address: 8530 W Roosevelt Ave,
Organization City: Visalia
Organization State: CA
Organization Zipcode: 93291
Organization Email: paul.klinker@dot.ca.gov
Organization Phone: (559) 974-1304
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: