Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 22225 DEA: HMA-RSRCH EFIS: HMA-RSRCH
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: In-house research studies for FHWA on Asphalt Mixture Performance Tester (AMPT) and Cracking Tolerance Index of Asphalt Mixtures (IDEAL CT)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2022-09-07-103
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Informational
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/07/2022
Date that the sample was received by the laboratory/organization performing the testing: 12/01/2022
The quantity of what the sample constitutes: 10 Boxes
A brief description of the sample: 3/4 RHMA-G
From where was the sample collected: Source
Laboratory sample identification: 023-003
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Construction -Ukiah
DIME Test ID: 2022-09-07-103-1
Test Method: ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
Data has not been verified.
DIME Test ID: 2022-09-07-103-2
Test Method: ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
Data has not been verified.
DIME Test ID: 2022-09-07-103-3
Test Method: ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
Data has not been verified.
DIME Test ID: 2022-09-07-103-8
Test Method: ASTM D8360-22: Standard Test Method for Determination of Rutting Tolerance Index of Asphalt Mixture Using the Ideal Rutting Test (Rutting Tolerance)
Verified Date: 04/04/2023
Date Tested: 02/02/2023
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of specimens
|
3
|
Conditioning temperature
|
50.0 °C
|
HMA Source
|
Plant Produced Mixture
|
Specimen preparation method
|
SGC
|
Specimen air voids
|
6.9 %
|
Specimen air voids 2
|
6.6 %
|
Specimen air voids 3
|
6.7 %
|
Specimen thickness
|
0.0620 m
|
Specimen thickness 2
|
0.0620 m
|
Specimen thickness 3
|
0.0620 m
|
Specimen diameter
|
0.1500 m
|
Specimen diameter 2
|
0.1500 m
|
Specimen diameter 3
|
0.1500 m
|
Peak load
|
4810.0 N
|
Peak load 2
|
5400.0 N
|
Peak load 3
|
6010.0 N
|
Shear strength
|
1446006 Pa
|
Shear strength 2
|
1623374 Pa
|
Shear strength 3
|
1806756 Pa
|
Rutting tolerance index
|
95.7
|
Rutting tolerance index 2
|
107.4
|
Rutting tolerance index 3
|
119.6
|
Average rutting tolerance index
|
107.6
|