Print Report | Back to Sample Detail

Sample Record for 2022-11-15-74

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88885 DEA: Geotechnical Investigations EFIS: Geotechnical Investigations QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for geotechnical investigations.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-11-15-74
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - FFS - Corrosion Laboratory
Sample Organization Contact: (916) 227-7287
Type of Sample: Per Request
Type of Material: Soil
Sample Taken Date: 11/15/2022
Date that the sample was received by the laboratory/organization performing the testing: 02/03/2023
The quantity of what the sample constitutes: NA
A brief description of the sample: Boring
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: NA

Material Information

The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: 07-LA-57-PM7.7
Where the material sample would have been placed if not sampled:

Test Results

Test 1 of 4

DIME Test ID: 2022-11-15-74-1
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 03/14/2023
Date Tested: 02/06/2023
Submitted By Organization: CT HQ - FFS - Corrosion Laboratory
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: CR20230049
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 139.19 Ohm-cm
Minimum soil resistivity at 15.5 696 Ohm-cm
Minimum soil resistance of the lab measurement 124 Ohms
Soil sample temperature 20.4 C
pH of soil 7.51

Test 2 of 4

DIME Test ID: 2022-11-15-74-2
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 03/14/2023
Date Tested: 02/06/2023
Submitted By Organization: CT HQ - FFS - Corrosion Laboratory
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: CR20230048
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 143.83 Ohm-cm
Minimum soil resistivity at 15.5 719 Ohm-cm
Minimum soil resistance of the lab measurement 127 Ohms
Soil sample temperature 20.8 C
pH of soil 7.41

Test 3 of 4

DIME Test ID: 2022-11-15-74-3
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 03/14/2023
Date Tested: 02/03/2023
Submitted By Organization: CT HQ - FFS - Corrosion Laboratory
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: CR20230047
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 182.52 Ohm-cm
Minimum soil resistivity at 15.5 913 Ohm-cm
Minimum soil resistance of the lab measurement 156 Ohms
Soil sample temperature 22.3 C
pH of soil 8.39

Test 4 of 4

DIME Test ID: 2022-11-15-74-4
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 03/14/2023
Date Tested: 02/03/2023
Submitted By Organization: CT HQ - FFS - Corrosion Laboratory
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: CR20230046
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 161.59 Ohm-cm
Minimum soil resistivity at 15.5 808 Ohm-cm
Minimum soil resistance of the lab measurement 139 Ohms
Soil sample temperature 22 C
pH of soil 8.37