Print Report | Back to Sample Detail

Sample Record for 2022-12-13-47

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88885 DEA: Geotechnical Investigations EFIS: Geotechnical Investigations QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for geotechnical investigations.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-12-13-47
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - FFS - Corrosion Laboratory
Sample Organization Contact: (916) 227-7287
Type of Sample: Per Request
Type of Material: Soil
Sample Taken Date: 12/13/2022
Date that the sample was received by the laboratory/organization performing the testing: 02/03/2023
The quantity of what the sample constitutes: NA
A brief description of the sample: Boring
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: NA

Material Information

The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: 07-LA-60-PM12.02
Where the material sample would have been placed if not sampled:

Test Results

Test 1 of 3

DIME Test ID: 2022-12-13-47-1
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 03/14/2023
Date Tested: 02/07/2023
Submitted By Organization: CT HQ - FFS - Corrosion Laboratory
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: CR20230052
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 166.5 Ohm-cm
Minimum soil resistivity at 15.5 833 Ohm-cm
Minimum soil resistance of the lab measurement 148 Ohms
Soil sample temperature 20.5 C
pH of soil 8.41

Test 2 of 3

DIME Test ID: 2022-12-13-47-2
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 03/14/2023
Date Tested: 02/06/2023
Submitted By Organization: CT HQ - FFS - Corrosion Laboratory
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: CR20230051
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 175.11 Ohm-cm
Minimum soil resistivity at 15.5 876 Ohm-cm
Minimum soil resistance of the lab measurement 156 Ohms
Soil sample temperature 20.4 C
pH of soil 9.1

Test 3 of 3

DIME Test ID: 2022-12-13-47-3
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 03/14/2023
Date Tested: 02/06/2023
Submitted By Organization: CT HQ - FFS - Corrosion Laboratory
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: CR20230050
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 221.63 Ohm-cm
Minimum soil resistivity at 15.5 1108 Ohm-cm
Minimum soil resistance of the lab measurement 197 Ohms
Soil sample temperature 20.5 C
pH of soil 11.23