Print Report | Back to Sample Detail

Sample Record for 2023-02-08-44

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88885 DEA: Geotechnical Investigations EFIS: Geotechnical Investigations QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for geotechnical investigations.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-02-08-44
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - FFS - Corrosion Laboratory
Sample Organization Contact: (916) 227-7287
Type of Sample: Per Request
Type of Material: Soil
Sample Taken Date: 02/08/2023
Date that the sample was received by the laboratory/organization performing the testing: 02/08/2023
The quantity of what the sample constitutes: NA
A brief description of the sample: Boring
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: NA

Material Information

The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: 07-LA-105-PM2
Where the material sample would have been placed if not sampled:

Test Results

Test 1 of 7

DIME Test ID: 2023-02-08-44-1
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 03/14/2023
Date Tested: 02/09/2023
Submitted By Organization: CT HQ - FFS - Corrosion Laboratory
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: CR20230063
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 133.62 Ohm-cm
Minimum soil resistivity at 15.5 668 Ohm-cm
Minimum soil resistance of the lab measurement 113 Ohms
Soil sample temperature 22.8 C
pH of soil 8.71

Test 2 of 7

DIME Test ID: 2023-02-08-44-2
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 03/14/2023
Date Tested: 02/09/2023
Submitted By Organization: CT HQ - FFS - Corrosion Laboratory
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: CR20230062
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 283.75 Ohm-cm
Minimum soil resistivity at 15.5 1419 Ohm-cm
Minimum soil resistance of the lab measurement 250 Ohms
Soil sample temperature 20.9 C
pH of soil 8.96

Test 3 of 7

DIME Test ID: 2023-02-08-44-3
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 03/14/2023
Date Tested: 02/09/2023
Submitted By Organization: CT HQ - FFS - Corrosion Laboratory
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: CR20230061
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 198.23 Ohm-cm
Minimum soil resistivity at 15.5 991 Ohm-cm
Minimum soil resistance of the lab measurement 172 Ohms
Soil sample temperature 21.6 C
pH of soil 9.14

Test 4 of 7

DIME Test ID: 2023-02-08-44-4
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 03/14/2023
Date Tested: 02/09/2023
Submitted By Organization: CT HQ - FFS - Corrosion Laboratory
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: CR20230060
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 263.9 Ohm-cm
Minimum soil resistivity at 15.5 1320 Ohm-cm
Minimum soil resistance of the lab measurement 232 Ohms
Soil sample temperature 21 C
pH of soil 8.76

Test 5 of 7

DIME Test ID: 2023-02-08-44-5
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 03/14/2023
Date Tested: 02/08/2023
Submitted By Organization: CT HQ - FFS - Corrosion Laboratory
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: CR20230059
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 106.95 Ohm-cm
Minimum soil resistivity at 15.5 535 Ohm-cm
Minimum soil resistance of the lab measurement 93 Ohms
Soil sample temperature 21.5 C
pH of soil 8.45

Test 6 of 7

DIME Test ID: 2023-02-08-44-6
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 03/14/2023
Date Tested: 02/08/2023
Submitted By Organization: CT HQ - FFS - Corrosion Laboratory
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: CR20230058
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 123.85 Ohm-cm
Minimum soil resistivity at 15.5 619 Ohm-cm
Minimum soil resistance of the lab measurement 107 Ohms
Soil sample temperature 21.8 C
pH of soil 8.4

Test 7 of 7

DIME Test ID: 2023-02-08-44-7
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 03/14/2023
Date Tested: 02/08/2023
Submitted By Organization: CT HQ - FFS - Corrosion Laboratory
Organization Address: ,
Organization City:
Organization State:
Organization Zipcode:
Organization Email: steven.seifert@dot.ca.gov
Organization Phone: (916) 227-8588
General Comments for this Test: CR20230057
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 234.33 Ohm-cm
Minimum soil resistivity at 15.5 1172 Ohm-cm
Minimum soil resistance of the lab measurement 206 Ohms
Soil sample temperature 21 C
pH of soil 8.7