Print Report | Back to Sample Detail

Sample Record for 2023-02-18-10

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215003 DEA: 040J6204 EFIS: 0414000019 QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-680-12.4/21.9
Work Description: REHABILITATE PAVEMENT - RPL APP/DEP SLABS, 14 BRIDGES
Location Description: ALAMEDA COUNTY AT SUNOL AND IN PLEASANTON AND DUBLIN FROM KOOPMANN ROAD UNDERCROSSING TO ALAMEDA COUNTY LINE
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 Townsgate Road, Suite 200, Westlake Village, CA 91361
Resident Engineer: Eddie Dike Structure Rep.: Betty Geng

Sample Information

DIME Sample ID: 2023-02-18-10
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Concord Field Laboratory
Sample Organization Contact: (510) 714-7019
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 02/18/2023
Date that the sample was received by the laboratory/organization performing the testing: 03/01/2023
The quantity of what the sample constitutes: 162CY
A brief description of the sample: PCC sample for CRCP
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Security Paving Pleasanton

Material Information

The concrete mix design number: G3-22-PRS-319
The truck number from where the sample was collected: 18
The batch plant ticket number from where the sample was collected: Unknown
Concrete batch plant: Vulcan Portable plant
The fabricator/manufacturer designation for the sample: Vulcan
A detailed description of where the material sample was collected: Concrete sample from loader bucket
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2023-02-18-10-1
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 03/22/2023
Date Tested: 03/01/2023
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens 3
Does the testing machine measure load or stress on the beam specimen? Stress
Fracture initiates in the tension surface Within the Middle Third of the Span Length
Fracture occurred at a capped section No
Is a beam dimensional correction factor used? Yes
Age of specimen 10 days
Modulus of rupture 750 psi
Modulus of rupture average 770 psi
Modulus of rupture 2 790 psi
Modulus of rupture 3 770 psi