Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215348 DEA: 060U4204 EFIS: 0616000004
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-99-R4.9/11.6
Work Description: CONSTRUCT CRCP, PLACE HMA, AND ROADWAY EXCAVATION.
Location Description: FRESNO COUNTY IN AND NEAR SELMA AND FOWLER FROM MCCALL AVENUE UNDERCROSSING TO 0.5 MILE NORTH OF MERCED STREET UNDERCROSSING
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 Townsgate Rd. Suite 200, Westlake Village CA 91361
Resident Engineer: Chris Wilfong Structure Rep.: Unknown
DIME Sample ID: 2023-02-16-21
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 417-5341
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 02/16/2023
Date that the sample was received by the laboratory/organization performing the testing: 02/17/2023
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 3/4 HMA-SP Type A
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Ashlan
DIME Test ID: 2023-02-16-21-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 02/21/2023
Date Tested: 02/17/2023
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 3240 North Millbrook Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93726
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
2056.0 g
|
Corrected Asphalt Binder Content
|
4.51 %
|
Mass Loss
|
103.1 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.36 %
|
Moisture Content
|
0.00 %
|
Temperature Compensation Factor
|
0.15 %
|
Test Temperature
|
538 F
|
DIME Test ID: 2023-02-16-21-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 03/03/2023
Date Tested: 02/27/2023
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 3240 North Millbrook Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93726
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test: Max = 2.620
Core 1 = 93.0%
Core 2 = 93.2%
Core 3 = 92.9%
Test Result Compliance: complies
Additional Comments When Verified:
Bulk Specific Gravity
|
2.436
|
Bulk Specific Gravity 2
|
2.442
|
Bulk Specific Gravity 3
|
2.433
|
Average Bulk Specific Gravity
|
2.437
|